main
John Lauer
Add JST GH libraries, native schematic parity and revised sensor harness study with reviewed clips
1ac01c3
{
"status": "candidate-not-adopted",
"sensor": "NTCLE428E3103H301A",
"housing": "GHR-03V-S",
"contacts": "2 x SSHL-002T-P0.2, installed contact geometry omitted pending crimp data",
"boardSha256": "0cdf5da9feb946b1c9feb8f0dfc16dd8ca866c36d565b0075b98faffc520111a",
"routes": [
{
"circuit": 1,
"pathLengthMm": 58.45769682087224,
"exactArcRadiusMm": 4.3,
"requiredMinimumRadiusMm": 4.25,
"rootStraightMm": 7.0,
"minimumFactoryLeadMm": 295,
"terminationAllowanceMm": 4,
"minimumSlackMm": 5,
"shortLeadFits": false,
"longLeadFits": true,
"provisionalCutLengthMm": 70
},
{
"circuit": 2,
"pathLengthMm": 60.55769682087224,
"exactArcRadiusMm": 4.3,
"requiredMinimumRadiusMm": 4.25,
"rootStraightMm": 8.25,
"minimumFactoryLeadMm": 295,
"terminationAllowanceMm": 4,
"minimumSlackMm": 5,
"shortLeadFits": false,
"longLeadFits": true,
"provisionalCutLengthMm": 70
}
],
"bodyConflicts": [],
"probeConflicts": [],
"wireOverlapMm3": 0.0,
"carrierSinkEnvelopeAndFanHarnessConflicts": [],
"sensorMetalTabNominalSideGapMm": 0.0825,
"sensorTopToSinkEnvelopeGapMm": 0.83,
"limits": [
"Maximum cylindrical body envelope is not exact manufacturer CAD.",
"Case edge contact and adhesive are unqualified; sensor must track metal case rather than airflow or plastic temperature.",
"Sensor coating must not be compressed; compatibility/strain relief remain unresolved.",
"40 +/-5 mm version is rejected for reach; the 300 +/-5 mm variant is evaluated with provisional trim lengths.",
"Checks include carrier, sink envelope and nominal fan harness; detailed heatsink relief, clamp, mating tools and tolerances remain excluded.",
"GH nominal insulation range includes0.85mm sensor wire; solder-dipped end preparation, crimp height, retention and tooling validation remain open.",
"Mated height7.3mm is drawing reference only; cavity/latch registration and tolerances are not qualified. The loose contact asset is not shown as an installed crimp.",
"No change to formal board, BOM, firmware, calibration or acceptance."
]
}