main
John Lauer
Verify top-access cooler mount and reconcile current BOM with internal inventory pricing
ae78bc0
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455
{
"status": "proposed-machining-study-not-stock-fit-or-fabrication-release",
"vendorCutSha256": "306b8284b7c2272bb9bb87f814019241663cd79225a2f1ac400816b8688d0116",
"carrierReviewSha256": "7a04569e27de2c7fcbcd918d85530f536e2cf98938b8393442844aff8531f2c5",
"rows": [
{
"xyMm": [
118.98,
45
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"stockVendorFinOverlapMm3": 0.0,
"proposedReliefDiameterMm": 6.2,
"proposedBaseHoleDiameterMm": 3.2,
"removedVolumeMm3": 58.63111627440958,
"afterProposedMachiningOverlapMm3": 0.0
},
{
"xyMm": [
182.09,
52
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"stockVendorFinOverlapMm3": 0.0,
"proposedReliefDiameterMm": 6.2,
"proposedBaseHoleDiameterMm": 3.2,
"removedVolumeMm3": 58.5245886920311,
"afterProposedMachiningOverlapMm3": 0.0
},
{
"xyMm": [
182.09,
86.168
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"stockVendorFinOverlapMm3": 0.0,
"proposedReliefDiameterMm": 6.2,
"proposedBaseHoleDiameterMm": 3.2,
"removedVolumeMm3": 58.52459016513603,
"afterProposedMachiningOverlapMm3": 0.0
}
],
"validMachinedSolid": true,
"removedTotalVolumeMm3": 175.6802951315767,
"limitations": [
"Exact nominal CAD intersections only; no tolerance, driver handle, machining fixture or physical service qualification.",
"Three clearance bores plus fin-root spotface/access reliefs are explicitly proposed. These are absent from stock125319. Source file is never modified.",
"The head-diameter sweep assumes a straight driver whose envelope fits within5.5mm; actual tool must be selected.",
"Local vendor CAD derivative is not redistributed.",
"Machining effort, burrs, dimensional tolerances, cost and effect on cooling are not qualified."
]
}