main
John Lauer
Verify top-access cooler mount and reconcile current BOM with internal inventory pricing
ae78bc0
{
"status": "local-manufacturer-fin-check-not-fabrication",
"vendorCutSha256": "306b8284b7c2272bb9bb87f814019241663cd79225a2f1ac400816b8688d0116",
"carrierReviewSha256": "e12846e7ae4dcd50366898c0a69ff57ea00fdee8a9b53e290f5ead079fc22f03",
"rows": [
{
"xyMm": [
118,
45
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"vendorFinOverlapMm3": 0.18837491565195322
},
{
"xyMm": [
183,
52
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"vendorFinOverlapMm3": 0.030499625091493187
},
{
"xyMm": [
183,
86.168
],
"headAndToolRadiusMm": 2.75,
"approachStartZmm": 14.362001,
"vendorFinOverlapMm3": 0.03049962509152545
}
],
"limitations": [
"Exact nominal CAD intersections only; no tolerance, driver handle, machining fixture or physical service qualification.",
"Base requires three proposed clearance holes, not present in the vendor stock model. Source file is never modified.",
"The head-diameter sweep assumes a straight driver whose envelope fits within5.5mm; actual tool must be selected.",
"Local vendor CAD derivative is not redistributed."
]
}