main
John Lauer Verify top-access cooler mount and reconcile current BOM with internal inventory pricing ae78bc0
{
  "status": "local-manufacturer-fin-check-not-fabrication",
  "vendorCutSha256": "306b8284b7c2272bb9bb87f814019241663cd79225a2f1ac400816b8688d0116",
  "carrierReviewSha256": "e12846e7ae4dcd50366898c0a69ff57ea00fdee8a9b53e290f5ead079fc22f03",
  "rows": [
    {
      "xyMm": [
        118,
        45
      ],
      "headAndToolRadiusMm": 2.75,
      "approachStartZmm": 14.362001,
      "vendorFinOverlapMm3": 0.18837491565195322
    },
    {
      "xyMm": [
        183,
        52
      ],
      "headAndToolRadiusMm": 2.75,
      "approachStartZmm": 14.362001,
      "vendorFinOverlapMm3": 0.030499625091493187
    },
    {
      "xyMm": [
        183,
        86.168
      ],
      "headAndToolRadiusMm": 2.75,
      "approachStartZmm": 14.362001,
      "vendorFinOverlapMm3": 0.03049962509152545
    }
  ],
  "limitations": [
    "Exact nominal CAD intersections only; no tolerance, driver handle, machining fixture or physical service qualification.",
    "Base requires three proposed clearance holes, not present in the vendor stock model. Source file is never modified.",
    "The head-diameter sweep assumes a straight driver whose envelope fits within5.5mm; actual tool must be selected.",
    "Local vendor CAD derivative is not redistributed."
  ]
}