main
John Lauer Continue larger cooler assembly with plugged-connector and rerouted fan-wire checks 63a5240
{
  "status": "nominal-harness-candidate-not-adopted",
  "boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
  "assemblyReviewSha256": "535df39c3e05d04a87de0f078df66b4ea80efacd925275c974d763ae4c8444c9",
  "routes": [
    {
      "signal": "5V",
      "pathLengthMm": 71.99592510181304,
      "provisionalBlankLengthMm": 85,
      "sampledMinimumBendRadiusMm": 4.564452264473247,
      "controlPointsMm": [
        [
          142.17153390593273,
          91.86673734152916,
          65.05
        ],
        [
          144,
          102,
          66.05
        ],
        [
          154.6,
          108,
          60
        ],
        [
          157.6,
          106,
          40
        ],
        [
          154.6,
          102,
          25
        ],
        [
          154.6,
          98,
          20
        ],
        [
          154.6,
          98,
          16.54
        ]
      ],
      "sinkOverlapMm3": 0.0,
      "sinkGapMm": 1.4201189389514897
    },
    {
      "signal": "GND",
      "pathLengthMm": 76.49536880662798,
      "provisionalBlankLengthMm": 90,
      "sampledMinimumBendRadiusMm": 3.5754871343147214,
      "controlPointsMm": [
        [
          142.17153390593273,
          91.86673734152916,
          67.59
        ],
        [
          144,
          105,
          68.59
        ],
        [
          152.06,
          111,
          60
        ],
        [
          155.06,
          109,
          40
        ],
        [
          152.06,
          104,
          25
        ],
        [
          152.06,
          98,
          20
        ],
        [
          152.06,
          98,
          16.54
        ]
      ],
      "sinkOverlapMm3": 0.0,
      "sinkGapMm": 1.3892472664337374
    },
    {
      "signal": "FG",
      "pathLengthMm": 82.34607022181427,
      "provisionalBlankLengthMm": 95,
      "sampledMinimumBendRadiusMm": 3.2309103685881357,
      "controlPointsMm": [
        [
          142.17153390593273,
          91.86673734152916,
          70.13
        ],
        [
          144,
          108,
          71.13
        ],
        [
          149.51999999999998,
          114,
          60
        ],
        [
          152.51999999999998,
          112,
          40
        ],
        [
          149.51999999999998,
          106,
          25
        ],
        [
          149.51999999999998,
          98,
          20
        ],
        [
          149.51999999999998,
          98,
          16.54
        ]
      ],
      "sinkOverlapMm3": 0.0,
      "sinkGapMm": 1.3922562983387516
    }
  ],
  "bodySensorAndWireConflicts": [],
  "rotorConflicts": [],
  "validSolids": true,
  "limitations": [
    "Spline geometry and nominal 1.2mm insulation diameter are a routing study; no manufacturer bend-radius, exit-position or strain-relief qualification.",
    "Provisional cuts include10mm allowance; preserve factory leads until physical assembly validation.",
    "No support structure, guard, thermal performance or full workcell clearance acceptance. Fan rotation capability retained but not measured RPM."
  ]
}