main
John Lauer
Continue larger cooler assembly with plugged-connector and rerouted fan-wire checks
63a5240
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150
{
"status": "nominal-harness-candidate-not-adopted",
"boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
"assemblyReviewSha256": "535df39c3e05d04a87de0f078df66b4ea80efacd925275c974d763ae4c8444c9",
"routes": [
{
"signal": "5V",
"pathLengthMm": 71.99592510181304,
"provisionalBlankLengthMm": 85,
"sampledMinimumBendRadiusMm": 4.564452264473247,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
65.05
],
[
144,
102,
66.05
],
[
154.6,
108,
60
],
[
157.6,
106,
40
],
[
154.6,
102,
25
],
[
154.6,
98,
20
],
[
154.6,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.4201189389514897
},
{
"signal": "GND",
"pathLengthMm": 76.49536880662798,
"provisionalBlankLengthMm": 90,
"sampledMinimumBendRadiusMm": 3.5754871343147214,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
67.59
],
[
144,
105,
68.59
],
[
152.06,
111,
60
],
[
155.06,
109,
40
],
[
152.06,
104,
25
],
[
152.06,
98,
20
],
[
152.06,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.3892472664337374
},
{
"signal": "FG",
"pathLengthMm": 82.34607022181427,
"provisionalBlankLengthMm": 95,
"sampledMinimumBendRadiusMm": 3.2309103685881357,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
70.13
],
[
144,
108,
71.13
],
[
149.51999999999998,
114,
60
],
[
152.51999999999998,
112,
40
],
[
149.51999999999998,
106,
25
],
[
149.51999999999998,
98,
20
],
[
149.51999999999998,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.3922562983387516
}
],
"bodySensorAndWireConflicts": [],
"rotorConflicts": [],
"validSolids": true,
"limitations": [
"Spline geometry and nominal 1.2mm insulation diameter are a routing study; no manufacturer bend-radius, exit-position or strain-relief qualification.",
"Provisional cuts include10mm allowance; preserve factory leads until physical assembly validation.",
"No support structure, guard, thermal performance or full workcell clearance acceptance. Fan rotation capability retained but not measured RPM."
]
}