main
John Lauer
Fix control session reconnect and document manufacturer cooler and carrier studies
2d111fd
{
"status": "nominal-support-layout-not-adopted",
"boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
"partCount": 16,
"fittedBodyCount": 91,
"probeCount": 13,
"conflicts": [],
"retentionHolesXYmm": [
[
116.5,
45
],
[
186.5,
52
],
[
186.5,
86.168
]
],
"retentionFastenerProposal": "Three nominalM3x8 socket screws through2mm seats into tapped sink base;6mm engagement,1.112mm nominal tip reserve before7.112mm base top",
"fastenerConflicts": [],
"limitations": [
"Independent of Q1 leads but still transfers cooler loads to PCB edge clamps; PCB/scaffold loading is not qualified.",
"Old0.8mm clamp-jaw assumption remains unqualified; do not print or fabricate this study.",
"Retention envelopes are not sourced fasteners or manufactured threads; machining access, thread-depth tolerances, torque, locking and pullout require validation.",
"Candidate includes fan screw clearance holes only, no approved screw/nut stack.",
"Nominal touching seats are intentional; tolerance and thermal expansion are excluded.",
"Carrier self-contact is not a validated manufactured joint; topology, materials and load tests remain required.",
"Left underside retention tool approach crosses PCB; seated-fastener clearance does not establish installation/service access. Assembly sequence or top-access revision remains required."
]
}