main
John Lauer Add nominal installed fan harness, single animated assembly GLB and reviewed state-cycle clip e37b089

Installed fan harness and motion study

This nominal assembly adds the three-wire fan connection to J9 on the actual v85 PCB. The model includes the Adom-added Harwin M20-1060300 housing and three simplified M20-1180046 contacts mating with J9's M20-9990346 header. The exact Sunon fan ships with flying leads; the connector is our custom termination.

J9 circuit Wire Signal
1 Red +5 V auxiliary
2 Black Ground
3 Yellow Tachometer FG

The unpolarized connector requires a circuit-1 orientation check. Do not infer polarity from housing fit. Prepare 3–4 mm stripped ends for the specified contacts and qualify the crimp; the factory strip length is different.

The nominal routes are about 42.4, 44.6 and 47.6 mm. With a provisional 10 mm allowance and rounding, the proposed blanks are 55, 55 and 60 mm. These are not released cut lengths. Validate the real exit, insertion, service slack, strain relief and bend radii before trimming the supplied 305 ±10 mm leads. Sampled minimum curve radii are 6.62, 5.07 and 3.79 mm; these are geometry measurements, not a manufacturer bend-radius approval.

Review data records no nominal wire-to-wire, fitted-body, probe, support/sink-envelope or rotor swept-volume intersections. Intentional connector mating with J9 and the illustrative fan lead exit are excluded from collision rejection. Connector retention details and contacts are simplified. No physical fit, cooling or insulation qualification is claimed.

The GLB preserves Fan.Rotor and Fan.Rotor.Revolution. State metadata and the instance-scoped controller bind simulated or measured RPM explicitly. Invalid telemetry pauses motion and becomes unknown. The demonstration uses simulated RPM and 1:500 visual time scaling; it is not hardware telemetry. The gentle 20-second demo pauses, ramps up, holds briefly, ramps down and rests.

The STEP contains connection geometry only. The fan and carrier models remain separate. All GLB coordinates use metres in the board's MP1-anchored Z-up frame; STEP uses millimetres. Source fan geometry is the MIT Adom nominal component from the reusable Sunon page, not manufacturer CAD. A source copy and license are included for reproducibility.

Run python3 tools/installed_fan_study.py in the project's isolated CadQuery environment. The tool reads the saved v85 body audit, carrier and board and refuses a changed board identity. It generates the geometry and report; it does not modify the PCB or control hardware.

Single assembly GLB combines the actual PCB, nominal carrier and this fan harness, preserving the rotor animation. Assembly state metadata binds that exact file. Assembly review records input hashes and structural checks; browser evidence separately confirms rotor movement and stopped state. The sink remains the transparent clearance envelope.