John Lauer Preserve board29, component assets and scaffold-fit correction candidate with reviewed footage c54169e
{
  "scope": "Isolated nominal Q1 formed-lead and raised cooling stack; not adopted or mechanically qualified",
  "baseBoard": "aiflow/run/board-28.kicad_pcb",
  "candidateBoard": "checkpoints/formed-stack-review/formed-stack-candidate.kicad_pcb",
  "tabTopAbovePcbMm": 6.575,
  "sinkBottomAbovePcbMm": 7.25,
  "fanBottomAbovePcbMm": 42,
  "fanTopAbovePcbMm": 62,
  "geometryReports": {
    "carrier": "mechanical/formed-stack-study/carrier/review.json",
    "fan": "mechanical/formed-stack-study/fan/review.json",
    "sensor": "mechanical/formed-stack-study/sensor/review.json",
    "interface": "mechanical/formed-stack-study/interface/review.json"
  },
  "collisionsDetected": false,
  "limitations": [
    "All geometry checks are nominal and use conservative fitted-body envelopes plus selected actual shapes.",
    "Sink fins/custom carrier details/fastener preload and tolerances remain unqualified.",
    "Sensor direct Harwin crimp is rejected pending compatible termination.",
    "Fan RPM is not airflow; thermal acceptance remains failed/unverified.",
    "No fabrication, physical assembly or bench test has occurred."
  ]
}