main
John Lauer Preserve board29, component assets and scaffold-fit correction candidate with reviewed footage c54169e
/home/adom/project/electronic-load-molecule/.venv/lib/python3.12/site-packages/cadquery/utils.py:82: FutureWarning: save will be removed in the next release.
  warn(f"{f.__name__} will be removed in the next release.", FutureWarning)
{
  "status": "candidate-not-adopted",
  "sensor": "NTCLE428E3103H301A",
  "housing": "M20-1060200",
  "contacts": "2 x M20-1180046 (simplified contact envelopes)",
  "boardSha256": "849358353b1d6d219e5276bbc8eaab1f2630cad20f4ff19eabd13f097f3f06a3",
  "routes": [
    {
      "circuit": 1,
      "pathLengthMm": 78.93057971344629,
      "exactArcRadiusMm": 4.3,
      "requiredMinimumRadiusMm": 4.25,
      "rootStraightMm": 7.0,
      "minimumFactoryLeadMm": 295,
      "terminationAllowanceMm": 4,
      "minimumSlackMm": 5,
      "shortLeadFits": false,
      "longLeadFits": true,
      "provisionalCutLengthMm": 90
    },
    {
      "circuit": 2,
      "pathLengthMm": 78.32810708712711,
      "exactArcRadiusMm": 4.3,
      "requiredMinimumRadiusMm": 4.25,
      "rootStraightMm": 8.200000000000003,
      "minimumFactoryLeadMm": 295,
      "terminationAllowanceMm": 4,
      "minimumSlackMm": 5,
      "shortLeadFits": false,
      "longLeadFits": true,
      "provisionalCutLengthMm": 90
    }
  ],
  "bodyConflicts": [],
  "probeConflicts": [],
  "wireOverlapMm3": 0.0,
  "carrierSinkEnvelopeAndFanHarnessConflicts": [],
  "sensorMetalTabNominalSideGapMm": 0.0825,
  "sensorTopToSinkEnvelopeGapMm": 0.83,
  "limits": [
    "Maximum cylindrical body envelope is not exact manufacturer CAD.",
    "Case edge contact and adhesive are unqualified; sensor must track metal case rather than airflow or plastic temperature.",
    "Sensor coating must not be compressed; compatibility/strain relief remain unresolved.",
    "40 +/-5 mm version is rejected for reach; the 300 +/-5 mm variant is evaluated with provisional trim lengths.",
    "Checks include carrier, sink envelope and nominal fan harness; detailed heatsink relief, clamp, mating tools and tolerances remain excluded.",
    "Direct Harwin sensor crimp is NOT accepted:0.85mm insulation below0.90mm specified minimum; termination redesign open.",
    "No change to formal board, BOM, firmware, calibration or acceptance."
  ]
}
OK: external command completed; its running time is in this session
Hint: Use exec for build, browser automation and other work outside AI Flow. Do not start an idle heartbeat; only actual work counts.