main
John Lauer
Preserve board29, component assets and scaffold-fit correction candidate with reviewed footage
c54169e
12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970
/home/adom/project/electronic-load-molecule/.venv/lib/python3.12/site-packages/cadquery/utils.py:82: FutureWarning: save will be removed in the next release.
warn(f"{f.__name__} will be removed in the next release.", FutureWarning)
{
"status": "nominal-installed-harness-study",
"boardSha256": "849358353b1d6d219e5276bbc8eaab1f2630cad20f4ff19eabd13f097f3f06a3",
"fan": "MF40200V1-1000U-G99",
"sourceFanGlbSha256": "629daff4b81acf3e45149202b41f425deffbcce23a0bbd003a48c08770d730cf",
"connector": "M20-1060300",
"contacts": "3 x M20-1180046",
"header": "J9 M20-9990346",
"leadPreparation": "Custom trim/retermination of factory 305 \u00b110 mm leads; provisional lengths only; 3\u20134 mm contact strip requirement",
"routes": [
{
"sampledMinimumBendRadiusMm": 6.464518770976996,
"circuit": 1,
"signal": "5V",
"pathLengthMm": 44.587613154235925,
"provisionalBlankLengthMm": 55,
"allowanceMm": 10,
"endpointMm": [
154.6,
98,
16.54
]
},
{
"sampledMinimumBendRadiusMm": 5.0738911130363675,
"circuit": 2,
"signal": "GND",
"pathLengthMm": 46.82449132901466,
"provisionalBlankLengthMm": 60,
"allowanceMm": 10,
"endpointMm": [
152.06,
98,
16.54
]
},
{
"sampledMinimumBendRadiusMm": 3.796274007147433,
"circuit": 3,
"signal": "FG",
"pathLengthMm": 49.80576857664547,
"provisionalBlankLengthMm": 60,
"allowanceMm": 10,
"endpointMm": [
149.51999999999998,
98,
16.54
]
}
],
"wireConflicts": [],
"bodyConflicts": [],
"probeConflicts": [],
"carrierOrSinkEnvelopeConflicts": [],
"rotorSweptVolumeConflicts": [],
"validSolids": true,
"rotorNode": "Fan.Rotor",
"animation": "Fan.Rotor.Revolution",
"limitations": [
"Fan body and rotor are Adom nominal geometry, not manufacturer CAD.",
"Nominal connector engagement and simplified contacts are not mating/crimp qualification.",
"Factory exit and 1.2 mm wire OD are illustrative; physical fit, bend radii, strain relief and service slack require validation.",
"Support checks exclude the nominal fan housing at the assumed lead exit; physical strain relief still needs validation.",
"No measured RPM, hardware I/O or fabrication release."
]
}
OK: external command completed; its running time is in this session
Hint: Use exec for build, browser automation and other work outside AI Flow. Do not start an idle heartbeat; only actual work counts.