Raised cooling stack study
This isolated candidate starts from board28 and replaces only Q1’s generic model with the drawing-led formed-lead study. It raises the tab to6.575mm, sink base to7.25mm and fan to42–62mm above the PCB. It is not adopted or qualified.
Native DRC reports0violations/0opens. Rebuilt carrier, fan leads, sensor route and AlN/PEEK interface have no detected nominal body/probe/rotor conflicts in the saved checks. Reports preserve their assumptions; this is not tolerance, forming, preload, airflow or thermal validation.
The shown sensor termination remains an unaccepted placeholder: its informational0.85mm insulation OD is below the Harwin contact’s0.90mm minimum. A JSTGH alternative is being reviewed separately; no connector substitution has occurred.
Sources and reproducible scripts are in tools/formed_stack, derived from the earlier studies by tools/prepare_formed_stack_scripts.py. The earlier studies remain unchanged. No manufacturing release.
# Raised cooling stack study
This isolated candidate starts from board28 and replaces only Q1’s generic model with the drawing-led formed-lead study. It raises the tab to6.575mm, sink base to7.25mm and fan to42–62mm above the PCB. It is not adopted or qualified.
Native DRC reports0violations/0opens. Rebuilt carrier, fan leads, sensor route and AlN/PEEK interface have no detected nominal body/probe/rotor conflicts in the saved checks. Reports preserve their assumptions; this is not tolerance, forming, preload, airflow or thermal validation.
The shown sensor termination remains an **unaccepted placeholder**: its informational0.85mm insulation OD is below the Harwin contact’s0.90mm minimum. A JSTGH alternative is being reviewed separately; no connector substitution has occurred.
Sources and reproducible scripts are in `tools/formed_stack`, derived from the earlier studies by `tools/prepare_formed_stack_scripts.py`. The earlier studies remain unchanged. No manufacturing release.