main
John Lauer
Add corrected fan guard, lifted mount clearance study and reviewed process clip
51efa39
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152
{
"status": "nominal-harness-candidate-not-adopted",
"boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
"assemblyReviewSha256": "535df39c3e05d04a87de0f078df66b4ea80efacd925275c974d763ae4c8444c9",
"routes": [
{
"signal": "5V",
"pathLengthMm": 72.64957153323846,
"provisionalBlankLengthMm": 85,
"sampledMinimumBendRadiusMm": 4.561026537899845,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
66.55
],
[
144,
102,
67.55
],
[
154.6,
108,
60
],
[
157.6,
106,
40
],
[
154.6,
102,
25
],
[
154.6,
98,
20
],
[
154.6,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.420180089789753
},
{
"signal": "GND",
"pathLengthMm": 77.46245379889592,
"provisionalBlankLengthMm": 90,
"sampledMinimumBendRadiusMm": 3.5708950052880333,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
69.09
],
[
144,
105,
70.09
],
[
152.06,
111,
60
],
[
155.06,
109,
40
],
[
152.06,
104,
25
],
[
152.06,
98,
20
],
[
152.06,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.3893334510725026
},
{
"signal": "FG",
"pathLengthMm": 83.56323974652753,
"provisionalBlankLengthMm": 95,
"sampledMinimumBendRadiusMm": 3.2358804441605282,
"controlPointsMm": [
[
142.17153390593273,
91.86673734152916,
71.63
],
[
144,
108,
72.63
],
[
149.51999999999998,
114,
60
],
[
152.51999999999998,
112,
40
],
[
149.51999999999998,
106,
25
],
[
149.51999999999998,
98,
20
],
[
149.51999999999998,
98,
16.54
]
],
"sinkOverlapMm3": 0.0,
"sinkGapMm": 1.3923466264462627
}
],
"bodySensorAndWireConflicts": [],
"rotorConflicts": [],
"validSolids": true,
"limitations": [
"Spline geometry and nominal 1.2mm insulation diameter are a routing study; no manufacturer bend-radius, exit-position or strain-relief qualification.",
"Provisional cuts include10mm allowance; preserve factory leads until physical assembly validation.",
"No support structure, guard, thermal performance or full workcell clearance acceptance. Fan rotation capability retained but not measured RPM."
],
"fanBaseZmm": 63.55,
"fanLiftMm": 1.5
}