main
John Lauer
Review cooling stack tolerance sensitivity and prototype spacer selection
8718929
{
"status": "worksheet-not-assembly-approval",
"inputs": {
"case_to_sink_mm": 2.795,
"isolator_mm": 0.635,
"film_mm": 0.02,
"measurement_uncertainty_mm": 0.025
},
"spacerTargetMm": 2.1,
"targetRangeFromSeparationMeasurementOnlyMm": [
2.075,
2.125
],
"limitations": [
"Measurement uncertainty is only for case-to-sink separation; isolator, film and spacer manufacturing errors are additional.",
"Maintain independent sink support. Do not use Q1 leads to establish the sink datum.",
"Actual film thickness/contact pressure and flatness must be established; this arithmetic does not qualify contact or electrical insulation.",
"Recalculate thermal resistance and re-run formal gates if the adopted stack differs from design/spec.json."
]
}