Thermal-interface alternatives remain screened candidates

The present AlN/grease calculation still uses an unqualified interface: the exact 178-25-220 outline and mounting-hole drawing are unresolved. The nominal PEEK fastener model does not close that gap.

Wakefield 175-6-220P has a published drawing (18.034 × 12.7 mm, 3.5814 mm hole, 0.1524 mm thickness). However, its catalog's 0.40 C/W entry is identified as a TO-3 / one-square-inch test. It cannot be copied into this TO-220 case-to-sink model as the actual interface resistance. The catalog also recommends 350–550 psi mounting pressure; the PEEK screw study does not establish that pressure. This alternative is not adopted merely because a distributor lists an attractive thermal-resistance number. Manufacturer catalog, printed pages 4–5.

Boyd 4169G provides a fully dimensioned 19.30 × 13.97 × 1.57 mm alumina option with a 3.68 mm hole. Its greater thickness changes sink height, fastener engagement and the thermal calculation. It is not interchangeable with the present 0.635 mm AlN assumption. Manufacturer catalog, printed page 100.

Next selection must bind an exact orderable insulator drawing, the contact area and pressure, compatible grease if required, fastener preload and tolerance stack. Recompute cooling and recheck assembled geometry together. No BOM, thermal limit or acceptance is changed by this review.

Board32 screening update

At 5.5 W, 40 °C ambient and the unchanged 55 °C case ceiling, the total case-to-ambient budget is 2.727 K/W. With the study's assumed 1.5 K/W forced-air sink, only 1.227 K/W remains for the complete interface and spreading path. This is a calculation, not proof of installed airflow.

Henkel SIL PAD TSP 3500 at 0.254 mm has manufacturer TO-220 reference results of 2.02 K/W at 50 psi and 1.37 K/W at 200 psi. Even the latter gives 55.79 °C in the simple all-heat-through-sink calculation before additional spreading allowance. It is therefore not adopted for this budget. At the nominal contact area, 200 psi would imply about 179 N clamp force; the existing fastener study does not establish that preload. These are reference values dependent on surfaces and pressure, not guaranteed assembly specifications. Manufacturer technical sheet.

The reproducible pressure sweep is in checkpoints/board32-interface-alternatives/tsp3500-review.json. No board, operating limit, or acceptance gate changed.

Current supplier-page conflict, checked 13 October 2026

Wakefield’s 178-25-220 product page calls the pad 25 × 14 × 0.635 mm in its title and description, but lists 20 × 14 × 0.635 mm under Product Size. R9 uses the latter as nominal geometry. Neither the outline nor mounting hole can be released from this conflicting text; a controlled drawing or fully documented alternative is still needed. Recorded discrepancy.