a794aa7
Short heatsink sensor harness — PH candidate
This is an unadopted design study, not the fabrication board. AIFlow board-7 remains the accepted workflow checkpoint. The supplied 150 mm sensor leads are cut to a short installed run; the extra supplied length is not coiled onto the board.
| Item | Candidate | Evidence / limitation |
|---|---|---|
| Sensor | Vishay NTCALUG01T103GA, 10 kΩ, 2%, B3984 | Manufacturer lug-body STEP retained; selected ordering variant supplies 150 ±10 mm leads |
| PCB header J10 | JST B2B-PH-K-S, 2 mm pitch | Native footprint/model; pin 1 TEMP_SENSE, pin 2 GND |
| Mating housing | JST PHR-2 | Published outer dimensions; undimensioned taper and cavities are illustrative, not validated mating CAD |
| Contacts | JST SPH-002T-P0.5S | Specified AWG30–24 and 0.8–1.5 mm insulation range covers the sensor's AWG26 and 0.93±0.1 mm insulation |
| Installed leads | Two individually curved routes, roughly 40 mm | Worst-case 1.03 mm OD modeled; final cut allowance, stripping, bend radius and crimp procedure remain unqualified |
| Mechanical mount | Dedicated M3 lug mount on sink underside near Q1 | Retains independent Q1 electrical insulation; physical preload/contact qualification pending |
The earlier GH contact's 1.00 mm maximum insulation diameter did not cover the sensor's full 1.03 mm maximum. This PH candidate resolves that specified range mismatch. It does not prove a good crimp or mechanical mating fit.
Native KiCad 10.0.5 reports zero DRC violations and zero unconnected items after refill. All 2463 pad/track/via net assignments survived native connectivity build, refill, save and reload. Schematic parity matches 112 components and 288 connected pins. These are electrical geometry checks, not thermal or physical qualification.
- DRC
- Net-intent preservation
- Native schematic parity
- Harness dimensions and assumptions
- Assembled candidate GLB
The current study clip is an actual viewer inspection, silent and without burned captions. It is separate from the approved main film. Solid-intersection and assembled probing checks remain required before adopting this revision. The fan's four-wire harness remains separate unfinished work; no second decorative wire set is accepted.
Sources: Vishay sensor, JST PH, JST GH.
# Short heatsink sensor harness — PH candidate
This is an **unadopted design study**, not the fabrication board. AIFlow board-7 remains the accepted workflow checkpoint. The supplied 150 mm sensor leads are cut to a short installed run; the extra supplied length is not coiled onto the board.
| Item | Candidate | Evidence / limitation |
|---|---|---|
| Sensor | Vishay NTCALUG01T103GA, 10 kΩ, 2%, B3984 | Manufacturer lug-body STEP retained; selected ordering variant supplies 150 ±10 mm leads |
| PCB header J10 | JST B2B-PH-K-S, 2 mm pitch | Native footprint/model; pin 1 TEMP_SENSE, pin 2 GND |
| Mating housing | JST PHR-2 | Published outer dimensions; undimensioned taper and cavities are illustrative, not validated mating CAD |
| Contacts | JST SPH-002T-P0.5S | Specified AWG30–24 and 0.8–1.5 mm insulation range covers the sensor's AWG26 and 0.93±0.1 mm insulation |
| Installed leads | Two individually curved routes, roughly 40 mm | Worst-case 1.03 mm OD modeled; final cut allowance, stripping, bend radius and crimp procedure remain unqualified |
| Mechanical mount | Dedicated M3 lug mount on sink underside near Q1 | Retains independent Q1 electrical insulation; physical preload/contact qualification pending |
The earlier GH contact's 1.00 mm maximum insulation diameter did not cover the sensor's full 1.03 mm maximum. This PH candidate resolves that specified range mismatch. It does not prove a good crimp or mechanical mating fit.
Native KiCad 10.0.5 reports **zero DRC violations and zero unconnected items** after refill. All **2463 pad/track/via net assignments** survived native connectivity build, refill, save and reload. Schematic parity matches **112 components and 288 connected pins**. These are electrical geometry checks, not thermal or physical qualification.
- [DRC](filled-drc.json)
- [Net-intent preservation](sensor-ph-filled.intent.json)
- [Native schematic parity](schematic/netlist-parity.json)
- [Harness dimensions and assumptions](sensor-harness-study.json)
- [Assembled candidate GLB](v8-review.glb)
The current study clip is an actual viewer inspection, silent and without burned captions. It is separate from the approved main film. Solid-intersection and assembled probing checks remain required before adopting this revision. The fan's four-wire harness remains separate unfinished work; no second decorative wire set is accepted.
Sources: [Vishay sensor](https://www.vishay.com/docs/29164/ntcalug01t.pdf), [JST PH](https://www.jst-mfg.com/product/pdf/eng/ePH.pdf), [JST GH](https://www.jst-mfg.com/product/pdf/eng/eGH.pdf).