main
John Lauer aiflow run compact-outline-candidate-codex-astra-20261013-2322: placement a794aa7

Short heatsink sensor harness — PH candidate

This is an unadopted design study, not the fabrication board. AIFlow board-7 remains the accepted workflow checkpoint. The supplied 150 mm sensor leads are cut to a short installed run; the extra supplied length is not coiled onto the board.

Item Candidate Evidence / limitation
Sensor Vishay NTCALUG01T103GA, 10 kΩ, 2%, B3984 Manufacturer lug-body STEP retained; selected ordering variant supplies 150 ±10 mm leads
PCB header J10 JST B2B-PH-K-S, 2 mm pitch Native footprint/model; pin 1 TEMP_SENSE, pin 2 GND
Mating housing JST PHR-2 Published outer dimensions; undimensioned taper and cavities are illustrative, not validated mating CAD
Contacts JST SPH-002T-P0.5S Specified AWG30–24 and 0.8–1.5 mm insulation range covers the sensor's AWG26 and 0.93±0.1 mm insulation
Installed leads Two individually curved routes, roughly 40 mm Worst-case 1.03 mm OD modeled; final cut allowance, stripping, bend radius and crimp procedure remain unqualified
Mechanical mount Dedicated M3 lug mount on sink underside near Q1 Retains independent Q1 electrical insulation; physical preload/contact qualification pending

The earlier GH contact's 1.00 mm maximum insulation diameter did not cover the sensor's full 1.03 mm maximum. This PH candidate resolves that specified range mismatch. It does not prove a good crimp or mechanical mating fit.

Native KiCad 10.0.5 reports zero DRC violations and zero unconnected items after refill. All 2463 pad/track/via net assignments survived native connectivity build, refill, save and reload. Schematic parity matches 112 components and 288 connected pins. These are electrical geometry checks, not thermal or physical qualification.

The current study clip is an actual viewer inspection, silent and without burned captions. It is separate from the approved main film. Solid-intersection and assembled probing checks remain required before adopting this revision. The fan's four-wire harness remains separate unfinished work; no second decorative wire set is accepted.

Sources: Vishay sensor, JST PH, JST GH.