R7 is AIFlow board-12. Native DRC has zero violations and zero opens. The filled-copper current-density gate passes, with only 0.47% margin at DUT_FUSED; this is not a manufacturing qualification.

The earlier R4/R5/R7 probing claims used stale project paths and were withdrawn. The corrected R7 run binds the actual selected board, display/plain GLBs, metadata, plan, layout, workcell and executable hashes. Access, stack, compile, collision, margins and coverage all pass. The large mounting pins remain unchanged; the probe uses medium J7.

On arav-rog, all 151 sequence-event midpoint snapshots reported solver OK, no obstacle snags and no jaw penetration beyond the existing tolerance. The browser verified the displayed model hash and checked 5,237 exported component/exclusion envelopes. This samples events; it is not continuous physical validation. CLI continuous sampling remains separate. The source fix is 8fcd114bca3dc76a708b186c0a341503b60a1459; owner tracker: https://wiki.adom.inc/adom/adom-aiflow-probing/issues/6. Registry and globally deployed runtimes have not been upgraded.

Thermal decision still open

The coupled, supplied-parameter scenario predicts Q1 junction rise 49.55°C still and 12.75°C moving at 5.5W. Q1's limit is 15°C; moving-air passage cannot waive still-air failure. D1 is 30.2°C still/21.5°C moving against the general 35°C limit. These are assumed package/interface/airflow parameters, not measured assembly properties or a spatial heatsink FEM.

A simple independent path bound requires heatsink-to-air resistance no higher than 1.607 K/W at 5.5W after allowing 0.42 K/W junction-to-case and 0.7 K/W interface. The assumed still-air 8 K/W sink cannot meet that bound. Its single-path 15°C-rise power is only 1.645W. That number is a sizing diagnostic, not an authorized derating or a change to the existing 5W cap.

To close thermal acceptance without weakening the gate, establish a real assembly path that meets the passive bound, or obtain a separately reviewed change to operating/fault requirements backed by shutdown transient evidence. Fan tach feedback alone cannot establish junction temperature during a stall. Keep load output locked until all engineering gates pass.

Evidence: revisions/compact-r11/current-repair-r7/assumed-probe-input-review.json, browser-event-sampling.json, thermal-sizing-review.json, and fields-package-scenario/fields.json.

Exact datasheet airflow check

The ATS-FPX040040035-66-C2-R0 manufacturer datasheet, checked 16 October 2026, gives 1.20 K/W ducted and 5.80 K/W unducted at 100 LFM (0.5 m/s). It provides forced-air points, not a natural-convection rating. Its dimensions are 40 × 40 × 35 mm with 45 × 45 mm hole spacing. The actual small Q1 contact area, interface, airflow distribution and mounting orientation still need assessment.

The earlier 1.2 K/W scenario is conditional on ducted catalog conditions. A side fan without verified containment cannot claim it. The exact-board unducted sensitivity solve predicts Q1 junction rise 37.67°C with airflow, still above its15°C limit; still-air rise remains49.55°C. D1 is30.2°C still/22.1°C moving. No acceptance limit or main specification changed.

Auxiliary power and fan replay follow-up

The R7 clip above demonstrates mechanical access. The older sequence omitted explicit PS2 commands and settling despite the authored plan. A separate probing-r7-aux-motion candidate preserves the same board while adding explicit simulated PS2 steps, real settle durations and input-bound component motion. Its validation is separate; it must not be described as a bench test, calibrated RPM, demonstrated cooling or closed-loop load-control qualification.

The auxiliary/motion candidate now passes all six exact-input nominal geometry stages. Native sequence review confirms PS2 events, 3/3/4-second settling and final auxiliary-off before ground removal. Linux and Windows each pass25 Rust tests; seven motion/obstacle JavaScript tests pass. Browser checks confirm rotor motion, stationary housing, off/half-speed/nominal-speed samples, shutdown, pause and backward seek. Source commit555d8b1e78f2b1eeb78199379be447ce0b4c4072 and owner issue7 include the reusable skill. This is task-local verified deployment; global release availability is separate.

The first native fan recording delayed action too long to show shutdown and was rejected. The synchronized second take includes both on and off states and is the published clip. Both raw recordings remain on arav-rog.

Supplier response reviewed 16 October 2026

ATS answered the sent technical request on 14 October. Their fine-pitch sink estimate is about 9 K/W in natural convection; the suggested coarse-pitch alternative is about 4.6 K/W. These are supplier estimates, not measurements of this assembly. Catalog tests heat the entire 40 × 40 mm base uniformly, unlike Q1's localized tab. A duct must constrain airflow through the fin channels to use the ducted curve.

With the existing 5.5 W screen, 0.42 K/W junction-to-case and assumed 0.7 K/W isolating interface, a simple series-path calculation gives 55.66°C junction rise for the fine-pitch sink and 31.46°C for the coarse-pitch alternative. Both exceed the unchanged 15°C limit. This is a sizing calculation, not a new spatial simulation or an accepted power rating. The supplier-informed coupled sensitivity is a separate input file; historical solves and the main acceptance specification are preserved.

ATS confirms the supplied T766 material does not electrically isolate. A bare C1 sink plus a separately specified isolator is a possible prototype route, but its installed thermal resistance and electrical withstand still need verification. Mounting-hole diameter depends on selected hardware; do not assume 3.0 mm and 3.175 mm are interchangeable.

The supplied envelope CAD excludes proprietary fin geometry and has no permission for redistribution. It is not included in this public project. Existing independently reconstructed geometry remains labeled approximate. Same Sky acknowledged the fan request; detailed control data remains outstanding.

Next design review: compare a genuinely lower-resistance passive assembly against a ducted fan-cooled assembly with a separately evidenced fan-fault shutdown path. Neither is approved by this screen. Keep the 5 W bring-up cap and load-output lock; do not silently replace still-air acceptance with a fan-on result. See supplier-cooling-screen.json and spec-package-supplier-informed.json under the R7 revision.

Corrected local-contact 3D sensitivity

The previous 12 × 18 mm contact assumption exceeded Q1's TO-220 outline. A separate corrected sensitivity uses an assumed 8 × 10 mm contact at 5.5 W. It does not claim the actual tab geometry. At 40°C ambient, the 1 mm model predicts maximum case-patch temperatures of 82.44°C with prescribed h=5 W/m²K and 49.20°C with h=50 W/m²K. The 2 mm mesh differs by less than 0.08°C. Energy-balance relative error is below 3e-13.

These are case temperatures, not junction temperatures. Prescribed h is not verified fan airflow and is not fitted to the supplier's 9 K/W full-base estimate. This spatial study must not substitute for package qualification. Inputs and per-body results are in revisions/compact-r11/current-repair-r7/thermal-contact-sensitivity/. No acceptance gate changed.

Larger passive comparison

The Wakefield125319/125320 sheet gives 1.5 K/W for a three-inch specimen in natural convection. A three-inch cut of125319 is approximately76.10 ×76.20 ×50.8mm; the sold stock is12in long. This exceeds the current72×72mm PCB in both planar directions, before brackets or probing clearances. It is not a compact drop-in40mm cooler.

Under the same assumed0.7K/W interface and0.42K/W package resistance, its catalog value gives14.41°C junction rise at5.5W: only0.59°C nominal margin to15°C. Catalog test temperature/orientation, local heat-source spreading, enclosure effects and actual interface must still be established. Do not treat that marginal calculation as an accepted passive design or procurement recommendation. A bigger cooler may satisfy the thermal requirement, but costs scaffold space; the alternate ducted approach still requires proven fan-fault protection.

Supplier-informed coupled solve completed

The immutable R7 board with9K/W still-air and5.8K/W moving-air inputs predicts Q1 junction rise54.87°C and37.67°C respectively. Both exceed Q1's15°C limit. The underlying Fields report incorrectly uses the global35°C budget in issue wording because the per-part override is ignored; owner issue16 records the reproducible defect. AIFlow's stricter acceptance remains unchanged. supplier-coupled-review.json independently compares the unmodified numerical outputs to15°C; it is not a solver fix or qualification.