f2ec9fd
Q1 drain land-pattern study
Candidate v82 uses Load:TO-220-3_Horizontal_TabUp_Drain1p6, derived from the installed KiCad TO-220 horizontal tab-up footprint. Only drain pad 2 width changes from 1.905 to 1.600 mm. Pad height remains 2.000 mm; the 1.100 mm drill, lead pitch, mechanical hole, body, courtyard and 3D placement remain unchanged. Nominal minimum annular ring is (1.600 − 1.100)/2 = 0.250 mm. This retains the project's preferred ring and does not tighten the lead-insertion hole.
The narrower drain land provides real separation from the neighboring high-current source exit. V77's 0.1 mm three-net study reports 56.09 LOAD_POS, 58.31 GND and 56.50 SHUNT_P A/mm², below the unchanged 60 screen. V82 combines this geometry with the PowerDI5 diode cooling study and passes native DRC with zero errors, warnings or opens. Its combined current/thermal solve is pending.
This is a project-specific assembly variant, not a new manufacturer-recommended footprint. Copper land reduction, solder fillet/process tolerance, mechanical lead stress and prototype assembly still need physical review. No fabrication release or live-board replacement has occurred. The complete native source footprint is retained under references/q1-land-pattern/; the variant is in kicad/lib/Load.pretty/.
# Q1 drain land-pattern study
Candidate v82 uses `Load:TO-220-3_Horizontal_TabUp_Drain1p6`, derived from the installed KiCad TO-220 horizontal tab-up footprint. Only drain pad 2 width changes from 1.905 to 1.600 mm. Pad height remains 2.000 mm; the 1.100 mm drill, lead pitch, mechanical hole, body, courtyard and 3D placement remain unchanged. Nominal minimum annular ring is (1.600 − 1.100)/2 = 0.250 mm. This retains the project's preferred ring and does not tighten the lead-insertion hole.
The narrower drain land provides real separation from the neighboring high-current source exit. V77's 0.1 mm three-net study reports 56.09 LOAD_POS, 58.31 GND and 56.50 SHUNT_P A/mm², below the unchanged 60 screen. V82 combines this geometry with the PowerDI5 diode cooling study and passes native DRC with zero errors, warnings or opens. Its combined current/thermal solve is pending.
This is a project-specific assembly variant, not a new manufacturer-recommended footprint. Copper land reduction, solder fillet/process tolerance, mechanical lead stress and prototype assembly still need physical review. No fabrication release or live-board replacement has occurred. The complete native source footprint is retained under `references/q1-land-pattern/`; the variant is in `kicad/lib/Load.pretty/`.