John Lauer Record current-screen milestone, combined cooling study and physical-pad solver review f2ec9fd

Latest: combined candidate v82

V77 passes the three-net fine-grid current screen (56.09/58.31/56.50 A/mm²). V80 PowerDI5 cooling predicts D1 rise 34.5°C still, 26.0°C with assumed moving convection; Q1 heat remains excluded. V82 combines the two changes and the named Q1 footprint variant: native DRC 0 errors, 0 warnings, 0 opens. The combined 0.1 mm solve is running. Duplicate diode anode pads currently use the legacy split in feasibility solves; explicit physical-pad selection is being implemented and must be validated before acceptance.

Clearing stale filled-zone polygons before rebuilding candidate connectivity resolved false via-net reassignment. Expected net membership is still checked before/after fill and after save/reload; native DRC remains mandatory. No live board change.

Source current and diode cooling refinement

AIFlow 0.1.82 remains published and installed; Fields PR9 is still under owner review. The shared Fields executable has not been replaced. The live board revision was rechecked on 10 October and remains unchanged.

V52 remains the best completed fine-grid three-net result: GND 58.31, LOAD_POS 56.11, SHUNT_P 64.25 A/mm² against the unchanged 60 screen. V58 worsened the source exit to 80.11 and was rejected. V63 added a parallel top-layer source connection but moved the peak onto its via (64.80); v67 tests a smaller, offset via and has zero native DRC errors, warnings and opens. Its fine-grid solve is pending.

V61 was rejected before save when native connectivity reassigned its conflicting LOAD_POS via to GND. Removing that via and preserving the ground repair produced DRC-clean v62. Its operating-heat diagnostic predicts D1 +39.3°C still air / +29.4°C moving air. Expanded bottom copper plus a calculated ground reconnection in DRC-clean v65 improves this to +38.5°C / +28.9°C, still above the 35°C budget. V68 explores more lateral spreading. These studies exclude Q1 heat and retain a conservative separate 3 A conductor screen; they do not establish full-board thermal acceptance.

No candidate is landed. Keep the native UUID/net invariant, original fabrication rules, physical heatsink/airflow qualification and complete same-board validation. Current/thermal/finish gates remain open. 71 raw takes, 18 reviewed excerpts, 14 storyboard clips; the final narrated film is not assembled.