Record unclipped current failures, Kelvin-return diagnostic and AIFlow 0.1.80
f4d2d15
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263
{
"formalAcceptance": false,
"kind": "copper-field-kelvin-return-voltage-diagnostic",
"inputIdentity": {
"algorithm": "sha256",
"board": "54f1aab0a34622d1c3675c13f4aeb7a678b0cee8b5a4d3bfd7484b10edb8dcf6",
"solverVersion": "0.6.2",
"spec": "c5d54ee5bfd4a7b6612f4a132a48dacc0abb34656e0241bafee9205b80910202"
},
"solverSha256": "17013baa2ba700870588f6be40434d08c0bfe24e9c08a4bc6f666f487a5934c5",
"source": "Isolated diagnostic fork of Fields PR6, logging 1 mm neighborhood means before display clipping",
"result": {
"amps": 0.006400819039631379,
"copperMm2": 57.3,
"iterations": 1274,
"jouleW": 0.0,
"layers": [
"F.Cu",
"B.Cu"
],
"net": "SHUNT_N_SENSE",
"peakAt": [
138.7,
82.69999999999999
],
"peakJ": 1.3,
"peakLayer": "B.Cu",
"platedPads": 0,
"residual": 7.721561438987511e-08,
"vias": 25
},
"terminalVoltsRelativeToRshuntSense": {
"RSH1.3": 0.0,
"U3.2": 0.0001849279868472694,
"R23.2": 0.0004612029987333694,
"C1.2": 0.0004251957830863694,
"R10.2": 0.0003304463472912694,
"TP13.1": 0.0005694939323354694,
"R19.2": 0.0004612579842573694,
"R28.2": 0.0004556460655607694,
"U2.4": 0.0004658550608479694,
"C3.2": 5.61669364582694e-05,
"C10.2": 0.0004490703301381694,
"C17.2": 0.0006740318129704693,
"C14.2": 7.97623189628394e-05,
"C12.2": 0.0004704310832547694,
"U4.7": 9.20520947530794e-05,
"U4.9": 0.0001173410680877694,
"C13.2": 0.0001656844856938694,
"U7.12": 0.0007183723656561693
},
"ina226EquivalentCurrentOffsetA": 0.00586705340438847,
"servoSetpointEquivalentOffsetA": 0.016693287962488597,
"limits": [
"Nominal 35 um copper and 25 um barrels, no temperature feedback",
"Maximum listed static IC supply currents under differing datasheet conditions; not a measured operating point",
"Comparator sink, dynamic gate current, startup and switching omitted",
"1 mm neighborhood mean is not an exact pad terminal voltage",
"RSH1 internal sense-to-power terminal parasitics excluded",
"Reported peakJ is a clipped display statistic, not acceptance maximum",
"No precision guarantee or calibration qualification"
]
}