main
John Lauer Record unclipped current failures, Kelvin-return diagnostic and AIFlow 0.1.80 f4d2d15
{
  "formalAcceptance": false,
  "kind": "copper-field-kelvin-return-voltage-diagnostic",
  "inputIdentity": {
    "algorithm": "sha256",
    "board": "54f1aab0a34622d1c3675c13f4aeb7a678b0cee8b5a4d3bfd7484b10edb8dcf6",
    "solverVersion": "0.6.2",
    "spec": "c5d54ee5bfd4a7b6612f4a132a48dacc0abb34656e0241bafee9205b80910202"
  },
  "solverSha256": "17013baa2ba700870588f6be40434d08c0bfe24e9c08a4bc6f666f487a5934c5",
  "source": "Isolated diagnostic fork of Fields PR6, logging 1 mm neighborhood means before display clipping",
  "result": {
    "amps": 0.006400819039631379,
    "copperMm2": 57.3,
    "iterations": 1274,
    "jouleW": 0.0,
    "layers": [
      "F.Cu",
      "B.Cu"
    ],
    "net": "SHUNT_N_SENSE",
    "peakAt": [
      138.7,
      82.69999999999999
    ],
    "peakJ": 1.3,
    "peakLayer": "B.Cu",
    "platedPads": 0,
    "residual": 7.721561438987511e-08,
    "vias": 25
  },
  "terminalVoltsRelativeToRshuntSense": {
    "RSH1.3": 0.0,
    "U3.2": 0.0001849279868472694,
    "R23.2": 0.0004612029987333694,
    "C1.2": 0.0004251957830863694,
    "R10.2": 0.0003304463472912694,
    "TP13.1": 0.0005694939323354694,
    "R19.2": 0.0004612579842573694,
    "R28.2": 0.0004556460655607694,
    "U2.4": 0.0004658550608479694,
    "C3.2": 5.61669364582694e-05,
    "C10.2": 0.0004490703301381694,
    "C17.2": 0.0006740318129704693,
    "C14.2": 7.97623189628394e-05,
    "C12.2": 0.0004704310832547694,
    "U4.7": 9.20520947530794e-05,
    "U4.9": 0.0001173410680877694,
    "C13.2": 0.0001656844856938694,
    "U7.12": 0.0007183723656561693
  },
  "ina226EquivalentCurrentOffsetA": 0.00586705340438847,
  "servoSetpointEquivalentOffsetA": 0.016693287962488597,
  "limits": [
    "Nominal 35 um copper and 25 um barrels, no temperature feedback",
    "Maximum listed static IC supply currents under differing datasheet conditions; not a measured operating point",
    "Comparator sink, dynamic gate current, startup and switching omitted",
    "1 mm neighborhood mean is not an exact pad terminal voltage",
    "RSH1 internal sense-to-power terminal parasitics excluded",
    "Reported peakJ is a clipped display statistic, not acceptance maximum",
    "No precision guarantee or calibration qualification"
  ]
}