John Lauer
Add parallel shunt current-transfer via and two reviewed close-up clips
4f1840c
{
"board": "checkpoints/before-shunt-via/adom-custom-electronic-load.kicad_pcb",
"boardSha256": "40b08c132317d30b5add5849b087d72ce241d69f1c8b9afdd2fe0fdd8380fb28",
"candidate": "checkpoints/power-width-review/v3/power-width-selective-v3.kicad_pcb",
"candidateSha256": "b7a51fae25f07a3602bdf82981222c42ca54c6f51517f42a087bc4de935d5aba",
"trackAndViaGeometryMatchesCandidate": true,
"segmentCount": 1674,
"viaCount": 253,
"comparison": "Native segment and via properties excluding UUID and lock metadata; full multisets compared. Does not assert identity of zone-fill caches.",
"drc": "design/power-width-saved-drc.json",
"drcSha256": "7c677c39a3432d9800a617dcd24b07538a1110738c94758c11aebc1f80cb98fe",
"violations": 0,
"unconnected": 0,
"ignoredChecks": [
{
"description": "Footprint has no courtyard defined",
"key": "missing_courtyard"
},
{
"description": "Track endpoint not centered on via",
"key": "track_not_centered_on_via"
},
{
"description": "Tuning profile track geometries",
"key": "tuning_profile_track_geometries"
},
{
"description": "Footprint doesn't match symbol's footprint filters",
"key": "footprint_filters_mismatch"
},
{
"description": "Footprint component type doesn't match footprint pads",
"key": "footprint_type_mismatch"
}
],
"qualification": "Engineering checkpoint only; not fabrication or power-rating approval."
}