main
John Lauer
Screen passive cooling alternatives without changing thermal acceptance
924128f
{
"status": "screen-only-not-adopted",
"source": "https://wakefieldthermal.com/content/catalogs/Thermal_Extrusions_WakefieldThermal-2025.pdf",
"pdfPage": 9,
"printedPage": 5,
"ambientC": 40,
"q1HeatW": 5.5,
"caseLimitC": 55,
"assumedInterfaceAndSpreadingCPerW": 0.52731,
"maximumSinkCPerW": 2.199962727272727,
"rows": [
{
"stockMpn": "125301",
"assumedCutLengthMm": 76.2,
"widthMm": 71.11999999999999,
"heightMm": 31.75,
"catalogNaturalCPerW": 2.9,
"conditionalCaseC": 58.850205
},
{
"stockMpn": "125313",
"assumedCutLengthMm": 76.2,
"widthMm": 73.02499999999999,
"heightMm": 33.324799999999996,
"catalogNaturalCPerW": 2.3,
"conditionalCaseC": 55.550205
},
{
"stockMpn": "125319",
"assumedCutLengthMm": 76.2,
"widthMm": 76.0984,
"heightMm": 50.8,
"catalogNaturalCPerW": 1.5,
"conditionalCaseC": 51.150205
}
],
"limits": [
"Catalog values refer to three-inch natural-convection specimens; operating rise, orientation and installation conditions are not fully specified.",
"Existing interface/spreading assumption has not been established for these extrusions.",
"No mounting, fan obstruction, price, final machining or assembly qualification.",
"No formal spec, board, thermal gate or BOM changes."
]
}