main
John Lauer
Continue exact component audit: comparator and servo assets, Q1 fit findings, clip inventory and supervisor progress ev…
9b93cb5
{
"part": "IXTP15N50L2",
"source": "https://www.littelfuse.com/~/media/electronics/datasheets/discrete_mosfets/littelfuse_discrete_mosfets_n-channel_linear_ixt_15n50_datasheet.pdf.pdf",
"drawing": "DS100054B (12/11) page 2 TO-220 outline",
"leadMaxWidthMm": 1.02,
"leadMaxThicknessMm": 0.56,
"leadMaxDiagonalMm": 1.1636150566231085,
"currentLibraryDrillMm": 1.1,
"verdict": "fails worst-case rectangular lead-envelope clearance before fabrication tolerances",
"candidateFinishedHoleMm": 1.4,
"candidateCopperPadMm": 2.2,
"unresolved": [
"Confirm minimum finished-hole tolerance and required assembly clearance",
"Reconcile horizontal lead forming, mounting-hole alignment and current/thermal impact before adopting board change"
],
"savedBoardEvidence": {
"file": "aiflow/run/board-24.kicad_pcb",
"sha256": "8827e2f804ff0e02766d40287416d814f66fbfa2780483ebdccd983adcb1ed26",
"q1PadFinishedDrillNominalMm": {
"1": 1.1,
"2": 1.1,
"3": 1.1
}
},
"shoulderConstraint": {
"maxShoulderLengthMm": 5.84,
"maxShoulderWidthMm": 1.65,
"straightLeadCatalogStandoffMm": 6.5,
"horizontalBodyToPadRowMm": 3.81,
"verdict": "Horizontal forming must bound where the wide shoulder ends; increasing the drill alone is insufficient."
}
}