main
John Lauer Adopt native-reviewed marked IC models and retain shared catalog repairs with inspection clip d7a7dc9
{
  "status": "ok",
  "data": {
    "discussion": {
      "id": 1784,
      "page_id": 215242,
      "author_name": "John Lauer",
      "title": "Fix virtual MPN exceeding usable package face",
      "body": "Versions: adom/ina226aidgst0.1.1, source57622c034d3b8d1ac82325342c645f6e0f7959dd. Shared AIFlow marking planner and STEP service.\n\nThe prior single-line MPN ran across the usable package face. Shared marking validation reported FAIL band and size/axis warnings. It overlapped the reserved area near the pin1 side rather than fitting within the available face.\n\nRebuilt only the virtual identification layer from the byte-identical KiCad-derived base model using planner defaults. The new two-line mark passes all gate checks; top and oblique renders inspected, pin1 retained. Published plain/marked and annotated-hero assets remain distinct. Source page readback matches. Live wiki interactive review and native board adoption remain separate.\n\nThe base remains explicitly generic nominal CAD under the KiCad library license exception; no new manufacturer-CAD or physical-qualification claim. Old marked model retained in review/. See provenance-correction.json.\n\n\n![ina226aidgst-etched.check](/attachments/adom/ina226aidgst/1cf4db833bc10e08e0fa8dd0fb622c551b561e3dd05586412d6c949ccc37d098/ina226aidgst-etched.check.png)\n\n[provenance-correction.json](/attachments/adom/ina226aidgst/004f15209c635437e013711e8cab834ce289cb1bb1c07227b0d6ad23f03debd6/provenance-correction.json)",
      "category": "bug-report",
      "is_pinned": 0,
      "is_locked": 0,
      "reply_count": 0,
      "last_reply_at": null,
      "created_at": "2026-10-11 17:52:29",
      "updated_at": "2026-10-11 17:52:29",
      "status": "open",
      "labels": "[]",
      "closed_at": null,
      "closed_by_name": null,
      "mentions_json": "[]",
      "number": 1,
      "deleted_at": null,
      "deleted_by_id": null,
      "deleted_by_name": null,
      "edited_at": null,
      "url": "https://wiki.adom.inc/adom/ina226aidgst/issues/1"
    },
    "page_discussion_count": 1
  },
  "hints": [
    {
      "level": "info",
      "code": "WEB_URL",
      "message": "https://wiki.adom.inc/adom/ina226aidgst/issues/1"
    },
    {
      "level": "info",
      "code": "BODY_POSTED",
      "message": "body posted (1274 chars): Versions: adom/ina226aidgst0.1.1, source57622c034d3b8d1ac82325342c645f6e0f7959dd. Shared AIFlow marking planner and STEP service.  The prior single-line MPN ran..."
    }
  ]
}