main
John Lauer Document finished-copper dependency, stackup sensitivity and grouped procurement gaps 549df8e
{
  "status": "finished-copper-capability-unconfirmed",
  "boardSha256": "1681eb90e49f4f229afe89bb75ff1738b7503907a52cd174e8b3d64b120082f4",
  "reviewedOn": "2026-10-10",
  "publicServiceAlias": "3rdPartyFab",
  "capabilityObservation": "Private capability guide lists 0.5 oz without establishing whether this is starting foil or guaranteed finished copper. Surface plating is described separately. User clarification requested; no answer assumed.",
  "acceptedAnalysis": {
    "finishedCopperUm": 35,
    "pitchMm": 0.1,
    "reference": "../unclipped-hotspots-v1/fields-v85-full-0p1/fields.json"
  },
  "thinCopperScreen": {
    "finishedCopperUm": 17.5,
    "pitchMm": 0.2,
    "reference": "fields-17p5um-0p2/fields.json",
    "barrelPlatingUm": 25,
    "barrelPlatingConfirmed": false
  },
  "limitAperMm2": 60,
  "nets": [
    {
      "net": "DUT_POS",
      "peak35umAt0p1mm": 53.4849967956543,
      "peak17p5umAt0p2mm": 94.16525268554688,
      "thinScreenPass": false
    },
    {
      "net": "LOAD_POS",
      "peak35umAt0p1mm": 40.110206604003906,
      "peak17p5umAt0p2mm": 85.5163345336914,
      "thinScreenPass": false
    },
    {
      "net": "SHUNT_P",
      "peak35umAt0p1mm": 56.50494384765625,
      "peak17p5umAt0p2mm": 110.34736633300781,
      "thinScreenPass": false
    },
    {
      "net": "GND",
      "peak35umAt0p1mm": 58.18177032470703,
      "peak17p5umAt0p2mm": 94.35797882080078,
      "thinScreenPass": false
    },
    {
      "net": "DUT_FUSED",
      "peak35umAt0p1mm": 50.66428756713867,
      "peak17p5umAt0p2mm": 83.45010375976562,
      "thinScreenPass": false
    },
    {
      "net": "5V_AUX",
      "peak35umAt0p1mm": 19.039779663085938,
      "peak17p5umAt0p2mm": 36.365814208984375,
      "thinScreenPass": true
    }
  ],
  "limitations": [
    "Different meshes: this comparison is not a quantified thickness-only convergence study.",
    "17.5 um screen cannot replace native board stackup or formal acceptance.",
    "35 um is an analysis assumption, not a confirmed process guarantee.",
    "No PCB geometry, power/current rating or gate threshold changed."
  ]
}