main
John Lauer
Review cumulative land candidates and correct complete STEP assembly clearance checks
ca3da55
{
"boardSha256": "cb22ba2a7213f5823c7d9dc399bc885a30f79eaba920d384ed9076d9531dcfa9",
"sourceFootprintSha256": "7dfd3371ef4571023611a81aade6f34a735380cd4d4b6e1ed18a545d3fcf7fa0",
"reference": "J10",
"mechanicalPads": {
"number": "MP",
"count": 2,
"net": null,
"geometry": [
{
"at": [
"-3.1",
"-1.4"
],
"size": [
"1",
"2.8"
],
"layers": [
"F.Cu",
"F.Mask",
"F.Paste"
]
},
{
"at": [
"3.1",
"-1.4"
],
"size": [
"1",
"2.8"
],
"layers": [
"F.Cu",
"F.Mask",
"F.Paste"
]
}
]
},
"signalPads": [
"1",
"2",
"3"
],
"classification": "Two soldered mechanical retention tabs, deliberately not schematic signal pins",
"sourceDrawing": "https://www.jst-mfg.com/product/pdf/eng/eGH.pdf page2 top-entry header",
"pass": true,
"limits": "Explicit supplemental audit only; no general audit findings suppressed and no physical joint or retention qualification."
}