7fa0c9c
Bourns CR0402 land-pattern candidate
This isolated candidate changes31 exact CR0402 references to a0.50mm inner gap,1.50mm overall span and0.50mm pad width. These are within the Bourns CR-series recommended ranges, p2. Existing generic pads measured0.48mm gap and0.64mm width.
Placement, traces, vias, net assignments and models remain unchanged. The first candidate incorrectly discarded the absolute pad angles on rotated footprints; native DRC rejected24 library mismatches. Version2 preserves the board angles and normalizes the standalone library to its local frame. Native DRC on version2 reports zero violations and zero opens with the full project library context.
Not yet adopted. Native visual/save comparison and schematic footprint binding synchronization remain. Manufacturer reference dimensions do not establish the assembly process or physical solder-joint reliability. The prior candidate and failed report remain in ../bourns-land-review.
The library is derived from the project’s KiCad stock R_0402 footprint with pad dimensions changed from the manufacturer drawing; retain KiCad library attribution/license. This is not Bourns-provided CAD and does not change part ratings.
# Bourns CR0402 land-pattern candidate
This isolated candidate changes31 exact CR0402 references to a0.50mm inner gap,1.50mm overall span and0.50mm pad width. These are within the [Bourns CR-series recommended ranges](https://www.bourns.com/docs/product-datasheets/cr.pdf), p2. Existing generic pads measured0.48mm gap and0.64mm width.
Placement, traces, vias, net assignments and models remain unchanged. The first candidate incorrectly discarded the absolute pad angles on rotated footprints; native DRC rejected24 library mismatches. Version2 preserves the board angles and normalizes the standalone library to its local frame. Native DRC on version2 reports zero violations and zero opens with the full project library context.
Not yet adopted. Native visual/save comparison and schematic footprint binding synchronization remain. Manufacturer reference dimensions do not establish the assembly process or physical solder-joint reliability. The prior candidate and failed report remain in ../bourns-land-review.
The library is derived from the project’s KiCad stock R_0402 footprint with pad dimensions changed from the manufacturer drawing; retain KiCad library attribution/license. This is not Bourns-provided CAD and does not change part ratings.