main
John Lauer
Catch larger-cooler contact gap and record revised spacer attachment study
eb056bf
{
"status": "numerically-passing-but-rejected-for-physical-contact-gap",
"boardSha256": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
"baseSpecSha256": "c1e57ab491b6fbd8d0386284eac84fcece54fcc167536b47a766552f53ab4df2",
"onlyAdditionalKey": "packageCooling",
"limitsUnchanged": true,
"physicalQualificationDeferredByUser": true,
"source": "https://wakefieldthermal.com/wakefield-thermal-3x12-in-extrusion-9099-125319/",
"modelScope": "Catalog nominal three-inch sink; moving condition deliberately uses same resistance, so fan benefit is not assumed. Installed validation later.",
"knownSensitivity": "Existing thermal-margin study retains failure cases at higher interface resistance or degraded convection; no guarantee inferred.",
"assemblyFinding": {
"gapMm": 2.12,
"review": "mechanical/passive-contact-study/review.json",
"replacementCandidate": "checkpoints/board32-contact-cooling/spec-candidate.json"
}
}