main
John Lauer Advance Board32 through current acceptance and retain unresolved thermal gate 1f15473
{
  "status": "unqualified-supplied-parameter-study",
  "inputIdentity": {
    "algorithm": "sha256",
    "board": "ea37ce6db20bae331bf41b6638fe9149a17c484e01bc2a0d7fd34917203b7fc3",
    "solverVersion": "0.6.2",
    "spec": "8cf415a8188e765176ba553a6c1c5c6364f090079ec2ddc512ebaf6b2c373b42"
  },
  "ambientC": 40,
  "caseLimitC": 55,
  "caseStillC": 75.58029316490774,
  "caseMovingC": 51.12754441575196,
  "junctionStillC": 77.89029316483575,
  "junctionMovingC": 53.4375444157522,
  "thermalGatePassed": false,
  "packageEnergyResidualMaxW": 2.3147519456756527e-09,
  "limits": [
    "Forced sink resistance assumes catalog 400 LFM, not measured installed airflow.",
    "Interface contact, lead conductance and physical assembly are unqualified.",
    "Full-power still-air exceeds case ceiling; no physical transient validation."
  ]
}