main
John Lauer
Advance Board32 through current acceptance and retain unresolved thermal gate
1f15473
5V_AUX: 0.3 A, 2 layer(s), 1555 iterations, residual 9.1e-8
DUT_FUSED: 3 A, 2 layer(s), 296 iterations, residual 9.1e-8
DUT_POS: 3.000220385674931 A, 2 layer(s), 1381 iterations, residual 9.6e-8
GND: 3 A, 2 layer(s), 15184 iterations, residual 1.0e-7
LOAD_POS: 3.0000289156626505 A, 2 layer(s), 2445 iterations, residual 9.7e-8
SHUNT_P: 3 A, 2 layer(s), 544 iterations, residual 8.9e-8
heat, still air: 3832 iterations, residual 1.0e-7
heat, moving air: 3108 iterations
OK: 6 nets solved, 3 hot parts, 1 issue(s), in 362.5 s: checkpoints/board32-package-cooling/full-0p1/fields.json
Hint: Peak current density 59 A/mm²; peak rise 34 °C still air, 25 °C moving air, budget 35 °C; Joule loss 0.088 W on top of 6.04335925925926 W from the tabs.
Hint: medium tab-rise: Q1: +38 °C at its thermal screening node in still air (+13 °C in moving air) against a 35 °C budget
Hint: Parts: skipped (--no-parts).
Hint: Heatsinks: 0; signal capacitance checks: 0; differential pairs: 0. Signals are screening estimates; unsupported geometry is reported, never certified.
Hint: Next: `adom-fields serve --fields checkpoints/board32-package-cooling/full-0p1` and open it (pup or the browser); `adom-fields ui view --quantity current --net <net>` drives it; `adom-fields tour` walks it for a video.
OK: external command completed; its running time is in this session
Hint: Use exec for build, browser automation and other work outside AI Flow. Do not start an idle heartbeat; only actual work counts.