main
John Lauer
Advance Board32 through current acceptance and retain unresolved thermal gate
1f15473
{
"candidate": "Wakefield 175-6-220P",
"source": "https://wakefieldthermal.com/content/data_sheets/Thermal%20Interface%20Materials.pdf",
"sourceSha256": "7d7f8019c6f6c0afff693ae1345015dda264aaf8d9109d090ffcab1ef2214413",
"sourcePage": 4,
"decision": "Not adopted. Do not apply advertised0.4K/W directly to this TO-220 contact.",
"thicknessMm": 0.1524,
"minimumConductivityCalPerCmSecondC": 0.0012,
"convertedConductivityWPerMK": 0.50208,
"nominalContactAreaMm2": 129.9618,
"bulkOnlyKPerW": 2.3355884951950303,
"manufacturerThermalResistanceTest": "0.40C/W for TO-3,1squareinch; not the selected TO-220 contact",
"recommendedPressurePsi": [
350,
550
],
"impliedForceAtNominalAreaN": [
313.61926059891,
492.83026665543
],
"limitations": [
"Bulk-only conduction excludes interface contact and spreading.",
"Catalog recommended pressure must be checked against PEEK fastening, tab flatness and creep.",
"Not a finished cooling BOM or thermal gate pass."
]
}