main
John Lauer
Advance Board32 through current acceptance and retain unresolved thermal gate
1f15473
OK: current analysis passed:
5V_AUX pass: the narrowest listed track carries the full specified load within 10 C
DUT_FUSED pass: branch currents give 3.79 C maximum track estimate against 10.00 C; barrel density 12.62 against 60.00 A/mm2; all through-terminal layer extremes checked
DUT_POS pass: branch currents give 3.59 C maximum track estimate against 10.00 C; barrel density 33.11 against 60.00 A/mm2; all through-terminal layer extremes checked
GND pass: pour on B.Cu+F.Cu (6358 mm2 filled) carries the load; tracks are 1.50 mm at most
LOAD_POS pass: pour on B.Cu+F.Cu (518 mm2 filled) carries the load; tracks are 1.75 mm at most
SHUNT_P pass: pour on B.Cu+F.Cu (39 mm2 filled) carries the load; tracks are 2.30 mm at most
Hint: Now do the analysis yourself, not only this table: draw the current density on the copper (amps per square millimetre on every loaded net's pours and tracks; a Laplace solve on the filled copper between the source pads and the sink pads is enough, the board file has the filled polygons) as a 1920x1080 PNG with a colour scale, then `artifact --kind analysis-image --file <png> --caption "..."`. It becomes a fullscreen shot in the final video and a figure on the run page.
Hint: Adom Fields 0.4.0 also supports specified conducting heatsinks, per-layer copper thickness, and an optional Signals view for overlap capacitance and differential-pair screening. Read its heatsinks-and-signals guide; use real assembly/material data, never invent a heatsink to pass this gate. Unsupported signal geometry is not a passing impedance result. adom-fields does this solve for you and shows it on the board in 3D: `adom-fields analyze --board <current board> --spec <spec> --out fields` (about two minutes), `adom-fields serve --fields fields &`, then under the fields step `tour fields` films the walkthrough; its screenshots are drawings you can register with `artifact`.
Hint: Then walk the pours this analysis judged on camera, under this same step: `tour nets --nets GND,LOAD_POS,SHUNT_P` (each net lit as a whole, pours and traces together, framed).
Hint: The heuristic and same-input Fields solve are engineering screens with documented assumptions, not manufacturing or thermal qualification.