main
John Lauer Verify current IC catalog lineage and resolve DGS manufacturer land patterns 9f7dac2
{
  "boardSha256": "a2b7fda1783e8b519a8819d93837c8d6fa5acb57dfde4f43abd2b3fd1b405bc5",
  "currentHead": "69c881ca71273b85415f6b63f0d67fa3eb9b9ca0",
  "plainStepBytesIdentical": true,
  "plainStepSha256": "be0e412f1c66fee70039b0e109e0cc7c823161dda97593718afa97569bc61ce3",
  "selectedBoardPadsMatchCurrentCatalog": true,
  "symbolPinCount": 32,
  "symbolChanges": {
    "2": {
      "selected": {
        "name": "PC14/OSC32_IN",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PC14-OSC32_IN",
        "electricalType": "bidirectional"
      }
    },
    "3": {
      "selected": {
        "name": "PC15/OSC32_OUT",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PC15-OSC32_OUT",
        "electricalType": "bidirectional"
      }
    },
    "6": {
      "selected": {
        "name": "PF2/NRST",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PF2-NRST",
        "electricalType": "bidirectional"
      }
    },
    "22": {
      "selected": {
        "name": "PA11/PA9",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PA11 [PA9]",
        "electricalType": "bidirectional"
      }
    },
    "23": {
      "selected": {
        "name": "PA12/PA10",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PA12 [PA10]",
        "electricalType": "bidirectional"
      }
    },
    "25": {
      "selected": {
        "name": "PA14/BOOT0",
        "electricalType": "bidirectional"
      },
      "current": {
        "name": "PA14-BOOT0",
        "electricalType": "bidirectional"
      }
    }
  },
  "review": "Six name changes are punctuation/alias formatting only: PC14/OSC32_IN, PC15/OSC32_OUT, PF2/NRST, PA11/PA9, PA12/PA10, PA14/BOOT0. Electrical-type changes, if any, are recorded separately below.",
  "electricalTypeChanges": {},
  "decision": "Retain Board31 selected marked STEP and previously reviewed symbol. Shared plain physical model is byte-identical; current source marks use a different derivative. New shared footprint returns to the same generic pad geometry already used by U1. No automatic update needed.",
  "limits": [
    "The current shared catalog views show a different marked derivative.",
    "Manufacturer example comparison and process qualification remain separate.",
    "No board change or gate advancement."
  ]
}