main
John Lauer
Publish review-only copper repair board with unchanged acceptance limits; current qualification remains open
9ad84f1
(version 1)
(rule "R0 conservative clearance" (constraint clearance (min 0.2mm)))
(rule "R0 signals" (constraint track_width (min 0.2mm)))
(rule "R0 via annulus" (constraint annular_width (min 0.15mm)))
(rule "R0 copper edge" (constraint edge_clearance (min 0.2mm)))
(rule "R0 drill" (constraint hole_size (min 0.3mm)))
(rule "R0 via diameter" (constraint via_diameter (min 0.6mm)))
# GCT USB4105 recommended land pattern has nominal 0.1944 mm copper-to-locating-hole clearance.
# Preserve the manufacturer lands and apply a local 0.15 mm hole clearance only within J8.
# This is above the selected profile copper-spacing minimum; drill-process DFM remains pending.
(rule "USB4105 manufacturer locating-hole pattern"
(condition "A.memberOfFootprint('J8') && B.memberOfFootprint('J8')")
(constraint hole_clearance (min 0.15mm)))
# 3rdPartyFab authoring policy (2026-10-15): References 0.8 mm, values 0.3 mm.
# Role-specific sizes are checked by v6-silk-applied.json; global minimum is 0.3 mm.
# Project stroke choices: reference 0.12 mm; value 0.05 mm. Print capability unverified.