Add narrated heatsink clearance investigation clip; distinguish nominal checks from physical qualification

John Lauer ·525717d7a3 · ·parent 6755ee4
4 files changed +15
docs/remote-service-clips.md+8
@@ -1,3 +1,11 @@+# Latest process clip: finding the pincer-clearance fault++This narrated 3D model review explains why raising the probe alone did not clear the heatsink: the pincer has an independent Z axis. It is retrospective model footage, not a recording of a successful workcell replay. The subsequent local CLI checks pass all six nominal probing stages with a 45 mm pincer rise and a cable-routing envelope outside the fin bank. Physical qualification and browser/CLI tether parity remain pending.++::adom-video{video="/adom/adom-custom-electronic-load/render/videos/remote-service/pincer-clearance-inspection.mp4" poster="/adom/adom-custom-electronic-load/render/videos/remote-service/pincer-clearance-inspection.jpg" captions="/adom/adom-custom-electronic-load/render/videos/remote-service/pincer-clearance-inspection.vtt"}++Recorded and narrated on arav-rog. Captions are selectable, not burned into the footage.+ > **Correction, 2026-10-16:** The TP16 probing clip below shows an invalid medium probe-pin connection to large MP1. Its previous probing-pass claim is withdrawn. Retained as design-history footage, not valid test-access evidence. The source fix rejects that mate. Revalidation using medium contact J7 found inadequate clearance to J1 wiring, so the board has returned to placement. A corrected successful replay is not available yet.  # Electronic-load design progression
videos/remote-service/pincer-clearance-inspection.jpgadded
⋯ 1 unchanged line ⋯
videos/remote-service/pincer-clearance-inspection.mp4added
⋯ 1 unchanged line ⋯
videos/remote-service/pincer-clearance-inspection.vttadded+7
@@ -0,0 +1,7 @@+WEBVTT
+
+00:00:00.000 --> 00:00:07.106
+The full replay catches the pincer crossing the heatsink fins. Raising the probe alone cannot fix this: the pincer has its own vertical axis.
+
+00:00:07.106 --> 00:00:10.298
+We are correcting that clearance and checking the ground wire again.