← Commit history
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/README.md+30−14
@@ -1,6 +1,6 @@ # AI Flow run: codex-astra on board-0 -**Running**: step `placement`, 137.6 min of AI time since the prompt (156.7 min on the wall clock). This page updates at every step change.+**Running**: step `routing`, 178.7 min of AI time since the prompt (197.9 min on the wall clock). This page updates at every step change.  Prompt at 2026-10-13T23:22:02.610999+00:00 (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -10,8 +10,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h  | Session | Prompt at | Done at | AI time min | Unobserved gap min | What | |---|---|---|---|---|---|-| 1 | 2026-10-13T23:22:02Z | (open) | 137.6 | 19 | the first prompt |-| **all** | | | **137.6** | | |+| 1 | 2026-10-13T23:22:02Z | (open) | 178.7 | 19 | the first prompt |+| **all** | | | **178.7** | | |  ## Per step @@ -20,11 +20,11 @@ AI time only, the idle cut out. | Step | AI min | AI thinking min | Tool min | Turns | Visits | Returns | Longest think | |---|---|---|---|---|---|---|---| | intake | 1.3 | 1.2 | 0.0 | 2 | 1 | 0 | 1.1 min |-| placement | 2.1 | 1.4 | 0.8 | 6 | 2 | 1 | 0.7 min |-| routing | 1.7 | 1.4 | 0.3 | 5 | 1 | 0 | 0.8 min |+| placement | 42.8 | 32.7 | 10.0 | 56 | 2 | 1 | 11.3 min |+| routing | 1.8 | 1.4 | 0.3 | 6 | 2 | 0 | 0.8 min | | pours | 0.1 | 0.0 | 0.1 | 3 | 1 | 0 | 0.0 min | | current | 0.1 | 0.0 | 0.1 | 4 | 1 | 0 | 0.0 min |-| thermal | 32.4 | 19.8 | 12.6 | 56 | 1 | 0 | 4.3 min |+| thermal | 32.8 | 19.8 | 13.0 | 56 | 1 | 0 | 4.3 min | | components | 3.4 | 3.2 | 0.3 | 3 | 1 | 0 | 1.2 min | | design | 14.6 | 14.3 | 0.3 | 6 | 1 | 0 | 13.3 min | | libraries | 19.3 | 17.6 | 1.7 | 14 | 1 | 0 | 8.0 min |@@ -33,7 +33,7 @@ AI time only, the idle cut out. | rules | 1.8 | 1.3 | 0.5 | 3 | 1 | 0 | 1.2 min | | test-plan | 0.9 | 0.7 | 0.2 | 3 | 1 | 0 | 0.6 min | | thermal-vias | 49.5 | 36.7 | 12.8 | 56 | 1 | 0 | 6.1 min |-| **total** | **137.6** | **105.7** | **31.9** | | | | |+| **total** | **178.7** | **137.1** | **41.6** | | | | |  ## Returns to earlier steps @@ -60,14 +60,10 @@ AI time only, the idle cut out. - 2026-10-14T01:26:30Z capture-stop - 2026-10-14T01:38:42Z artifact analysis-image for thermal-1: Q1 external heat-path sensitivity study on v2. Hypothetical interface and airflow; not a spatial fin solve, thermal acceptance or higher rating. - 2026-10-14T01:43:34Z artifact design-review for thermal-1: R11 v4 current and native DRC pass; thermal and assembled probe gates remain open.+- 2026-10-14T01:58:47Z capture-stop  ## Where the board stands -- routing: 0 unrouted after null passes-- gate: 0 new DRC errors, 0 unconnected, null inherited-- landed live: 0 of 0 route entries-- copper kept (mm2 per layer): {"B.Cu":3453.23,"F.Cu":3108.72}-- analyze-current: pass  ## The steps on camera @@ -299,7 +295,27 @@ What this step does: place the parts for routability, current and heat; the bina  Why the AI came back here: Corrected probing obstacle detection found cooler interference during ground-pin insertion and TP14 travel; propose moving J7 and TP14 into the left access corridor. -**Clip: placement, visit 2 (rework), still recording (started 2026-10-14T01:58:44Z); it appears here when the step ends.**+**Clip: placement, visit 2 (rework), the PCB editor from 2026-10-14T01:58:44Z to 2026-10-14T01:58:47Z. Motion only: 0.1 min of real time, 0 s of it had something moving; the clock in the corner is the real elapsed time.**++<video width="100%" controls><source src="/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/placement-2.mp4" type="video/mp4"></video>++**Contact sheet: nine frames spread through the placement, visit 2 (rework) clip, what the camera saw.**++![nine frames of placement, visit 2 (rework)](/blob/app/adom-custom-electronic-load/docs/runs/compact-outline-candidate-codex-astra-20261013-2322/placement-2-sheet.png)++### placement, visit 2++What this step does: place the parts for routability, current and heat; the binary packs, checks courtyards and lands moves; reserve visible space for connector labels and the two-sided service silkscreen; the switch-node check refuses switch copper under another part or a switch loop longer than the spec allows, and sends the AI back here++**Clip: placement, visit 2, still recording (started 2026-10-14T02:39:02Z); it appears here when the step ends.**++### routing, visit 2++What this step does: route to 100 percent with the spec's rules, gate with KiCad's DRC, land as undo steps; the AI takes it with take route=ai++Why the AI came back here: V5 contact relocation and local PWM detour pass native checks; revalidate the adopted board++**Clip: routing, visit 2, still recording (started 2026-10-14T02:39:53Z); it appears here when the step ends.**  ## Plan usage, the second cost line @@ -310,7 +326,7 @@ Percent of each plan limit used, as the provider reports it, at the start of the | claude | 5h | 2 % | 3 % | 1.0 % | | claude | Fable | 2 % | 2 % | 0.0 % | | claude | week | 41 % | 41 % | 0.0 % |-| codex | week | 14 % | 23 % | 9.0 % |+| codex | week | 14 % | 25 % | 11.0 % |  *The limits are per account, not per run: every AI thread signed in as this user draws on the same numbers, so a run made while other threads were working shows their usage too. Read it as an upper bound unless this run was the only thread active.* 
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/placement-2-sheet.pngadded
⋯ 1 unchanged line ⋯
docs/runs/compact-outline-candidate-codex-astra-20261013-2322/placement-2.mp4added
⋯ 1 unchanged line ⋯