← Commit history
README.md+33−27@@ -8,22 +8,22 @@ ACS720KLATR-35AB-T-4 from Allegro MicroSystems, LLC, in a SOIC-16. Pinout and pi | Pin | Name | Type | Function | |---|---|---|---|-| 1 | IP+ | passive | Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side. |-| 2 | IP+ | passive | Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side. |-| 3 | IP+ | passive | Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side. |-| 4 | IP+ | passive | Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side. |-| 5 | IP- | passive | Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side. |-| 6 | IP- | passive | Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side. |-| 7 | IP- | passive | Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side. |-| 8 | IP- | passive | Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side. |-| 9 | GND | power_in | Signal ground terminal. |-| 10 | FAULT_S | output | Open drain slow fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ. |-| 11 | FILTER | passive | Add a capacitor to set the output filter pole location. |-| 12 | VIOUT | output | Analog output signal; the output swings from 0 to 3 V with a 1.5 V zero-current output. |-| 13 | FAULT_F | output | Open drain fast fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ. |-| 14 | VCC | power_in | Device power supply terminal; supply voltage is 4.5 V minimum, 5.0 V typical and 5.5 V maximum. |-| 15 | VOC_F | input | Sets the trip current level for the fast fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC. |-| 16 | VOC_S | input | Sets the trip current level for the slow fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC. |+| 1 | IP+ | passive | Terminal for the current being sensed (primary conductor, positive side), fused internally. |+| 2 | IP+ | passive | Terminal for the current being sensed (primary conductor, positive side), fused internally. |+| 3 | IP+ | passive | Terminal for the current being sensed (primary conductor, positive side), fused internally. |+| 4 | IP+ | passive | Terminal for the current being sensed (primary conductor, positive side), fused internally. |+| 5 | IP- | passive | Terminal for the current being sensed (primary conductor, negative side), fused internally. |+| 6 | IP- | passive | Terminal for the current being sensed (primary conductor, negative side), fused internally. |+| 7 | IP- | passive | Terminal for the current being sensed (primary conductor, negative side), fused internally. |+| 8 | IP- | passive | Terminal for the current being sensed (primary conductor, negative side), fused internally. |+| 9 | GND | power_in | Signal ground terminal for the device. |+| 10 | FAULT_S | output | Open-drain slow fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage. |+| 11 | FILTER | passive | Add a capacitor here to set the output filter pole location (internal filter resistance RF(INT) typ. 1.7 kΩ). |+| 12 | VIOUT | output | Analog output signal, 0 to 3 V swing with 1.5 V zero-current output; output source current typ. 3 mA and sink current typ. 30 mA. |+| 13 | FAULT_F | output | Open-drain fast fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage. |+| 14 | VCC | power_in | Device power supply terminal, 4.5 V to 5.5 V (5.0 V typical). |+| 15 | VOC_F | input | Sets the trip current level for the fast fault; acceptable input range is 0.3 × VCC to 0.7 × VCC. |+| 16 | VOC_S | input | Sets the trip current level for the slow fault; acceptable input range is 0.3 × VCC to 0.7 × VCC. | ## Key specifications @@ -40,7 +40,7 @@ Limits as printed in the datasheet (page.json `metadata.characteristics` carries | Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page | |---|---|---|---|---|---|---|---|-| Supply Voltage | VCC | 4.5 | 5 | 5.5 | V | | 5 |+| Supply Voltage | VCC | 4.5 | 5 | 5.5 | V | Over full range of TA | 5 | | Supply Current | ICC | | 13 | 16 | mA | VCC = 5.0 V, output open | 5 | | Output Capacitance Load | CL | | | 10 | nF | VIOUT to GND | 5 | | Output Resistive Load | RL | 10 | | | kΩ | VIOUT to GND, VIOUT to VCC | 5 |@@ -55,14 +55,14 @@ Limits as printed in the datasheet (page.json `metadata.characteristics` carries | Sensitivity Error | ESENS | -4 | 1.5 | 4 | % | IP = IPR(max), TA = -40°C to 25°C | 10 | | Offset Voltage | VOE | -10 | 3.5 | 10 | mV | IP = 0 A, TA = 25°C to 125°C | 10 | | Offset Voltage | VOE | -30 | 9 | 30 | mV | IP = 0 A, TA = -40°C to 25°C | 10 |-| Fast Fault Error (positive IP) | EFF(HIGH)+ | -10 | 5 | 10 | % | VOC_F = 0.7 × VCC, Positive IP, TA = 25°C | 10 |-| Fast Fault Error (negative IP) | EFF(HIGH)- | -10 | 5 | 10 | % | VOC_F = 0.7 × VCC, Negative IP, TA = 25°C | 10 |-| Fast Fault Error (negative IP) | EFF(HIGH)- | -15 | 10 | 15 | % | VOC_F = 0.7 × VCC, Negative IP, TA = 25°C to 125°C | 10 |-| Fast Fault Error (positive IP, low trip) | EFF(LOW)+ | -20 | 12 | 20 | % | VOC_F = 0.38 × VCC, Positive IP, TA = 25°C | 10 |-| Fast Fault Error (negative IP, low trip) | EFF(LOW)- | -20 | 12 | 20 | % | VOC_F = 0.38 × VCC, Negative IP, TA = 25°C | 10 |-| Fast Fault Error (negative IP, low trip) | EFF(LOW)- | -30 | 18 | 30 | % | VOC_F = 0.38 × VCC, Negative IP, TA = 25°C to 125°C | 10 |-| Slow Fault Error (high trip) | ESF(HIGH) | -6 | 3 | 6 | % | VOC_S = 0.7 × VCC, IP rising | 10 |-| Slow Fault Error (low trip) | ESF(LOW) | -10 | 5 | 10 | % | VOC_S = 0.3 × VCC, IP rising | 10 |+| Fast Fault Error (high, positive IP) | EFF(HIGH)+ | -10 | 5 | 10 | % | VOC_F = 0.7 × VCC, Positive IP, TA = 25°C | 10 |+| Fast Fault Error (high, negative IP) | EFF(HIGH)- | -10 | 5 | 10 | % | VOC_F = 0.7 × VCC, Negative IP, TA = 25°C | 10 |+| Fast Fault Error (high, negative IP) | EFF(HIGH)- | -15 | 10 | 15 | % | VOC_F = 0.7 × VCC, Negative IP, TA = 25°C to 125°C | 10 |+| Fast Fault Error (low, positive IP) | EFF(LOW)+ | -20 | 12 | 20 | % | VOC_F = 0.38 × VCC, Positive IP, TA = 25°C | 10 |+| Fast Fault Error (low, negative IP) | EFF(LOW)- | -20 | 12 | 20 | % | VOC_F = 0.38 × VCC, Negative IP, TA = 25°C | 10 |+| Fast Fault Error (low, negative IP) | EFF(LOW)- | -30 | 18 | 30 | % | VOC_F = 0.38 × VCC, Negative IP, TA = 25°C to 125°C | 10 |+| Slow Fault Error (high) | ESF(HIGH) | -6 | 3 | 6 | % | VOC_S = 0.7 × VCC, IP rising | 10 |+| Slow Fault Error (low) | ESF(LOW) | -10 | 5 | 10 | % | VOC_S = 0.3 × VCC, IP rising | 10 | | Supply Voltage | VCC | | | 6 | V | | 3 | | Reverse Supply Voltage | VRCC | -0.5 | | | V | | 3 | | Filter Voltage | VFILTER | | | 25 | V | | 3 |@@ -70,9 +70,15 @@ Limits as printed in the datasheet (page.json `metadata.characteristics` carries | Reverse Output Voltage | VRIOUT, VRFAULT_S, VRFAULT_F | -0.5 | | | V | | 3 | | Reverse Input Pin Voltages | VROC_S, VROC_F | -0.5 | | | V | | 3 | | Maximum Continuous Current | ICMAX | | | 55 | A | TA = 25°C | 3 |-| Operating Ambient Temperature | TA | -40 | | 125 | °C | Range K | 3 |+| Operating Ambient Temperature Range K | TA | -40 | | 125 | °C | Range K | 3 | | Junction Temperature | TJ(max) | | | 165 | °C | | 3 | | Storage Temperature | Tstg | -65 | | 170 | °C | | 3 |+| Clearance | Dcl | 7.5 | | | mm | Minimum distance through air from IP leads to signal leads | 3 |+| Creepage | Dcr | 7.5 | | | mm | Minimum distance along package body from IP leads to signal leads | 3 |+| Working Voltage for Basic Isolation | VWVBI | | | 870 | VPK or VDC | Basic (single) isolation according to UL 60950-1 (edition 2) | 3 |+| Working Voltage for Basic Isolation | VWVBI | | | 616 | VRMS | Basic (single) isolation according to UL 60950-1 (edition 2) | 3 |+| Human Body Model ESD | VHBM | -7 | | 7 | kV | Per AEC-Q100 | 3 |+| Charged Device Model ESD | VCDM | -1 | | 1 | kV | Per AEC-Q100 | 3 | | Junction-to-Ambient Thermal Resistance | RθJA | | 17 | | °C/W | Mounted on the Allegro ASEK732/3 evaluation board | 4 | | Junction-to-Lead Thermal Resistance | RθJL | | 5 | | °C/W | Mounted on the Allegro ASEK732/3 evaluation board | 4 | @@ -95,7 +101,7 @@ As the datasheet states them (page.json `metadata.appearance`; the 3D model's co Data extracted from the manufacturer datasheet, not a distributor listing: -- **Datasheet:** [Allegro MicroSystems, LLC datasheet](docs/acs720klatr-35ab-t-4-datasheet.pdf) (35 pp, sha256 `c9ef0edb0725da48`, retrieved 2026-11-13, tier: lcsc)+- **Datasheet:** [Allegro MicroSystems, LLC datasheet](docs/acs720klatr-35ab-t-4-datasheet.pdf) (35 pp, sha256 `c9ef0edb0725da48`, retrieved 2026-11-17, tier: lcsc) - **Extractor:** parts-factory `2.0.0` / `extract_pins 0.3`, primary `claude-haiku-5-5` (text), consensus `claude-sonnet-5-5` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - **CAD:** KiCad official libraries (CC-BY-SA 4.0).
package.json+24−25@@ -1,6 +1,6 @@ { "slug": "acs720klatr-35ab-t-4",- "version": "0.1.2",+ "version": "0.1.3", "type": "component", "description": "Allegro MicroSystems, LLC Current Sensors, SOIC-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -53,7 +53,7 @@ "mouser": "250-720KLATR35ABT4" }, "distributor_check": {- "checked_at": "2026-11-13T01:18:01Z",+ "checked_at": "2026-11-17T21:55:58Z", "source": "Component Ocean /api/assign-pns", "digikey": { "pn": "620-ACS720KLATR-35AB-T-4-ND",@@ -69,97 +69,97 @@ "number": "1", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "2", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "3", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "4", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "5", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "6", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "7", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "8", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "9", "name": "GND", "type": "power_in",- "description": "Signal ground terminal."+ "description": "Signal ground terminal for the device." }, { "number": "10", "name": "FAULT_S", "type": "output",- "description": "Open drain slow fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ."+ "description": "Open-drain slow fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage." }, { "number": "11", "name": "FILTER", "type": "passive",- "description": "Add a capacitor to set the output filter pole location."+ "description": "Add a capacitor here to set the output filter pole location (internal filter resistance RF(INT) typ. 1.7 kΩ)." }, { "number": "12", "name": "VIOUT", "type": "output",- "description": "Analog output signal; the output swings from 0 to 3 V with a 1.5 V zero-current output."+ "description": "Analog output signal, 0 to 3 V swing with 1.5 V zero-current output; output source current typ. 3 mA and sink current typ. 30 mA." }, { "number": "13", "name": "FAULT_F", "type": "output",- "description": "Open drain fast fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ."+ "description": "Open-drain fast fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage." }, { "number": "14", "name": "VCC", "type": "power_in",- "description": "Device power supply terminal; supply voltage is 4.5 V minimum, 5.0 V typical and 5.5 V maximum."+ "description": "Device power supply terminal, 4.5 V to 5.5 V (5.0 V typical)." }, { "number": "15", "name": "VOC_F", "type": "input",- "description": "Sets the trip current level for the fast fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC."+ "description": "Sets the trip current level for the fast fault; acceptable input range is 0.3 × VCC to 0.7 × VCC." }, { "number": "16", "name": "VOC_S", "type": "input",- "description": "Sets the trip current level for the slow fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC."+ "description": "Sets the trip current level for the slow fault; acceptable input range is 0.3 × VCC to 0.7 × VCC." } ], "provenance": {@@ -173,12 +173,11 @@ "consensus": "agreed", "guards": "pin_guards 0.1: passed", "guard_notes": [- "extractor flagged: Pinout is taken from the single LA (SOICW-16) pinout diagram and terminal table, which apply to all ; Pin types are inferred, since the datasheet gives no ERC classes: IP+/IP- and FILTER are typed passi; The FAULT_S and FAULT_F pull-up resistance range (4.7 kΩ to 500 kΩ) is quoted from the Common Operat",- "2/16 pins cited to the wrong page (name found elsewhere): ['15:VOC_F@p27', '16:VOC_S@p27']"+ "extractor flagged: The datasheet covers the ACS720KLATR-35AB-T-4 variant (the -4 suffix only changes the fast fault mas" ], "pages_sent": 35,- "cost_usd": 0.1736,- "at": "2026-11-13T01:17:49"+ "cost_usd": 0.1723,+ "at": "2026-11-17T21:55:32" }, "datasheet": { "url": "https://datasheet.lcsc.com/datasheet/pdf/03cb04351fb680f38635607915ad0902.pdf",@@ -215,7 +214,7 @@ "centre_offset_mm": 0.0, "footprint_binding": "identity", "sha256": "d5eeddb4c0b304dc61950919b126fc61d7586abd5f16ab71a2a79759ec6498bf",- "checked": "2026-11-13",+ "checked": "2026-11-17", "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" }, {@@ -233,8 +232,8 @@ "zmin_mm": -0.0, "centre_offset_mm": 0.0, "footprint_binding": "identity",- "sha256": "94a312c9447de2c805f2f209d76244ab798394a6350e3a464a75681a66adc682",- "checked": "2026-11-13",+ "sha256": "b844fd5793628d3e19098809bc3a5b2f12d2f0c2b1492df361c212347f89e31a",+ "checked": "2026-11-17", "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]
page.json+27−26@@ -4,7 +4,7 @@ "slug": "acs720klatr-35ab-t-4", "title": "ACS720KLATR-35AB-T-4", "brief": "Allegro MicroSystems, LLC Current Sensors, SOIC-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.2",+ "version": "0.1.3", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -36,7 +36,7 @@ "mouser": "250-720KLATR35ABT4" }, "distributor_check": {- "checked_at": "2026-11-13T01:18:01Z",+ "checked_at": "2026-11-17T21:55:58Z", "source": "Component Ocean /api/assign-pns", "digikey": { "pn": "620-ACS720KLATR-35AB-T-4-ND",@@ -52,97 +52,97 @@ "number": "1", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "2", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "3", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "4", "name": "IP+", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 1 through 4 are the primary conductor terminals on the IP+ side."+ "description": "Terminal for the current being sensed (primary conductor, positive side), fused internally." }, { "number": "5", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "6", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "7", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "8", "name": "IP–", "type": "passive",- "description": "Terminal for the current being sensed; fused internally. Pins 5 through 8 are the primary conductor terminals on the IP- side."+ "description": "Terminal for the current being sensed (primary conductor, negative side), fused internally." }, { "number": "9", "name": "GND", "type": "power_in",- "description": "Signal ground terminal."+ "description": "Signal ground terminal for the device." }, { "number": "10", "name": "FAULT_S", "type": "output",- "description": "Open drain slow fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ."+ "description": "Open-drain slow fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage." }, { "number": "11", "name": "FILTER", "type": "passive",- "description": "Add a capacitor to set the output filter pole location."+ "description": "Add a capacitor here to set the output filter pole location (internal filter resistance RF(INT) typ. 1.7 kΩ)." }, { "number": "12", "name": "VIOUT", "type": "output",- "description": "Analog output signal; the output swings from 0 to 3 V with a 1.5 V zero-current output."+ "description": "Analog output signal, 0 to 3 V swing with 1.5 V zero-current output; output source current typ. 3 mA and sink current typ. 30 mA." }, { "number": "13", "name": "FAULT_F", "type": "output",- "description": "Open drain fast fault output, low true; it is pulled up externally, with fault pull-up resistance RPU of 4.7 kΩ to 500 kΩ."+ "description": "Open-drain fast fault output, low true; pull up externally (RPU 4.7 kΩ to 500 kΩ) to a compatible logic voltage." }, { "number": "14", "name": "VCC", "type": "power_in",- "description": "Device power supply terminal; supply voltage is 4.5 V minimum, 5.0 V typical and 5.5 V maximum."+ "description": "Device power supply terminal, 4.5 V to 5.5 V (5.0 V typical)." }, { "number": "15", "name": "VOC_F", "type": "input",- "description": "Sets the trip current level for the fast fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC."+ "description": "Sets the trip current level for the fast fault; acceptable input range is 0.3 × VCC to 0.7 × VCC." }, { "number": "16", "name": "VOC_S", "type": "input",- "description": "Sets the trip current level for the slow fault; the acceptable input range is 0.3 × VCC to 0.7 × VCC."+ "description": "Sets the trip current level for the slow fault; acceptable input range is 0.3 × VCC to 0.7 × VCC." } ], "provenance": {@@ -156,12 +156,11 @@ "consensus": "agreed", "guards": "pin_guards 0.1: passed", "guard_notes": [- "extractor flagged: Pinout is taken from the single LA (SOICW-16) pinout diagram and terminal table, which apply to all ; Pin types are inferred, since the datasheet gives no ERC classes: IP+/IP- and FILTER are typed passi; The FAULT_S and FAULT_F pull-up resistance range (4.7 kΩ to 500 kΩ) is quoted from the Common Operat",- "2/16 pins cited to the wrong page (name found elsewhere): ['15:VOC_F@p27', '16:VOC_S@p27']"+ "extractor flagged: The datasheet covers the ACS720KLATR-35AB-T-4 variant (the -4 suffix only changes the fast fault mas" ], "pages_sent": 35,- "cost_usd": 0.1736,- "at": "2026-11-13T01:17:49"+ "cost_usd": 0.1723,+ "at": "2026-11-17T21:55:32" }, "datasheet": { "url": "https://datasheet.lcsc.com/datasheet/pdf/03cb04351fb680f38635607915ad0902.pdf",@@ -198,7 +197,7 @@ "centre_offset_mm": 0, "footprint_binding": "identity", "sha256": "d5eeddb4c0b304dc61950919b126fc61d7586abd5f16ab71a2a79759ec6498bf",- "checked": "2026-11-13",+ "checked": "2026-11-17", "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" }, {@@ -216,8 +215,8 @@ "zmin_mm": 0, "centre_offset_mm": 0, "footprint_binding": "identity",- "sha256": "94a312c9447de2c805f2f209d76244ab798394a6350e3a464a75681a66adc682",- "checked": "2026-11-13",+ "sha256": "b844fd5793628d3e19098809bc3a5b2f12d2f0c2b1492df361c212347f89e31a",+ "checked": "2026-11-17", "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]@@ -705,5 +704,7 @@ ], "visibility": { "public": true- }+ },+ "description": "Allegro MicroSystems, LLC Current Sensors, SOIC-16. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }