← Commit history

Set visibility: public

Ray ·95240bd0b8 ·1mo ago ·parent 02b60c4
1 file changed +8−5
page.json+8−5
@@ -44,7 +44,7 @@         "number": "3",         "name": "IP-",         "type": "passive",-        "description": "Terminal for current being sensed (negative/return side of the internal copper conduction path). Fused internally with pin 4; tie both externally. Primary conductor resistance is ~1.2 m\u03a9 for the LC package."+        "description": "Terminal for current being sensed (negative/return side of the internal copper conduction path). Fused internally with pin 4; tie both externally. Primary conductor resistance is ~1.2 mΩ for the LC package."       },       {         "number": "4",@@ -62,19 +62,19 @@         "number": "6",         "name": "FAULT",         "type": "output",-        "description": "Overcurrent fault output, active low, open-drain style requiring an external pull-up (RPU \u2265 1 k\u03a9, typ. to VCC). Trips and latches when |IP| exceeds \u00b1100% of the full-scale range (\u00b112.5 A for the 12AB variant); response time ~1.3 \u00b5s. Cleared only by cycling VCC below VCCFR (200 mV max) for at least tCCFR (100 \u00b5s)."+        "description": "Overcurrent fault output, active low, open-drain style requiring an external pull-up (RPU ≥ 1 kΩ, typ. to VCC). Trips and latches when |IP| exceeds ±100% of the full-scale range (±12.5 A for the 12AB variant); response time ~1.3 µs. Cleared only by cycling VCC below VCCFR (200 mV max) for at least tCCFR (100 µs)."       },       {         "number": "7",         "name": "VIOUT",         "type": "output",-        "description": "Analog output voltage, ratiometric to VCC, with positive slope proportional to current flowing from IP+ to IP-. Quiescent output is VCC/2 at IP=0 A; sensitivity is 110 mV/A (typ) for the 12AB variant. Drives up to CLOAD=1 nF with RLOAD \u2265 15 k\u03a9."+        "description": "Analog output voltage, ratiometric to VCC, with positive slope proportional to current flowing from IP+ to IP-. Quiescent output is VCC/2 at IP=0 A; sensitivity is 110 mV/A (typ) for the 12AB variant. Drives up to CLOAD=1 nF with RLOAD ≥ 15 kΩ."       },       {         "number": "8",         "name": "VCC",         "type": "power_in",-        "description": "Device power supply terminal. Operates from 3 to 5.5 V single supply (3.3 V nominal); ICC ~4 mA typ, 5.5 mA max. Bypass with 0.1 \u00b5F (CBYP) to GND close to the pin."+        "description": "Device power supply terminal. Operates from 3 to 5.5 V single supply (3.3 V nominal); ICC ~4 mA typ, 5.5 mA max. Bypass with 0.1 µF (CBYP) to GND close to the pin."       }     ],     "provenance": {@@ -138,5 +138,8 @@     "docs/acs711elctr-12ab-t-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file