main
Ray
Set visibility: public
0041636
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856857858859860861862863864865866867868869870871872873874875876877878879880881882883884885886887888889890891892893894895896897898899900901902903904905906907908909910911912913914915916917918919920921922923924925926927928929930931932933934935936937938939940941942943944945946947948949950951952953954955956957958959960961962963964965966967968969970971972973974975976977978979980981982983984985986987988989990991992993994995996997998999
{
"schema_version": 1,
"type": "component",
"slug": "acs37002kmabtr-050b3",
"title": "ACS37002KMABTR-050B3",
"brief": "Allegro MicroSystems, LLC Current Sensors, SOIC-16-300mil. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"sensors",
"acs37002kmabtr-050b3",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "ACS37002KMABTR-050B3",
"manufacturer": "Allegro MicroSystems, LLC",
"package": "SOIC-16-300mil",
"pin_count": 16,
"category": "Sensors",
"subcategory": "Current Sensors",
"datasheet": "https://datasheet.lcsc.com/datasheet/pdf/25d49d471aebfea6a3521341f31b275b.pdf",
"parts": {
"symbol": "acs37002kmabtr-050b3.kicad_sym",
"footprint": "acs37002kmabtr-050b3.kicad_mod",
"model_3d": "acs37002kmabtr-050b3-hero.glb",
"model_3d_plain": "acs37002kmabtr-050b3-etched.glb",
"model_3d_step": "acs37002kmabtr-050b3-etched.step",
"model_3d_step_plain": "acs37002kmabtr-050b3.step",
"lbr": "acs37002kmabtr-050b3.lbr"
},
"distributor_links": {
"lcsc": "C1512016",
"digikey": "620-ACS37002KMABTR-050B3TR-ND",
"mouser": "250-37002KMABTR050B3"
},
"distributor_check": {
"checked_at": "2026-11-11T00:06:10Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "620-ACS37002KMABTR-050B3TR-ND",
"status": "found",
"lifecycle": "Active"
},
"mouser": {
"pn": "250-37002KMABTR050B3",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "IP+",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "2",
"name": "IP+",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "3",
"name": "IP+",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "4",
"name": "IP+",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "5",
"name": "IP-",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "6",
"name": "IP-",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "7",
"name": "IP-",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "8",
"name": "IP-",
"type": "passive",
"description": "Terminal for the current being sensed, fused internally; primary conductor resistance is 0.85 mΩ for the MA package at 25°C."
},
{
"number": "9",
"name": "OCF",
"type": "output",
"description": "Overcurrent fault output, open-drain and active low; requires an external pull-up with RPU between 4.7 kΩ and 500 kΩ."
},
{
"number": "10",
"name": "VCC",
"type": "power_in",
"description": "Device power supply; 3.3 V devices operate from 3.15 V to 3.6 V, with a 0.1 µF VCC-to-GND bypass capacitor recommended."
},
{
"number": "11",
"name": "VOC",
"type": "input",
"description": "Overcurrent fault operation point input; 0.33 V to 1.32 V sets the trip point on 3.3 V devices, and a voltage below 0.1 V selects the internal EEPROM fault level, with CVOC at most 1 nF."
},
{
"number": "12",
"name": "VIOUT",
"type": "output",
"description": "Analog output representing the current through IP; the linear operating range is 0.3 V to 3.0 V on 3.3 V devices, with RL at least 10 kΩ and CL at most 6 nF."
},
{
"number": "13",
"name": "VREF",
"type": "power_in",
"description": "Zero-current voltage reference; 1.64 V to 1.66 V on bidirectional 3.3 V devices, with RVREF at least 10 kΩ and CVREF at most 6 nF."
},
{
"number": "14",
"name": "GAIN_SEL_1",
"type": "input",
"description": "Gain selection bit 1; logic high requires at least 2.25 V and logic low is at most 0.5 V on 3.3 V devices, with an internal 1 MΩ pull-down to GND."
},
{
"number": "15",
"name": "GND",
"type": "power_in",
"description": "Device ground terminal."
},
{
"number": "16",
"name": "GAIN_SEL_0",
"type": "input",
"description": "Gain selection bit 0; logic high requires at least 2.25 V and logic low is at most 0.5 V on 3.3 V devices, with an internal 1 MΩ pull-down to GND."
}
],
"provenance": {
"extractor": "extract_pins 0.3",
"factory_chain": {
"factory": "2.0.0",
"extractor": "extract_pins 0.3",
"primary_model": "claude-haiku-5-5",
"primary_mode": "text",
"consensus_model": "claude-sonnet-5-5",
"consensus": "agreed",
"guards": "pin_guards 0.1: passed",
"guard_notes": [
"extractor flagged: The datasheet pinout (Figure 2 and terminal list) is shared by the MA and LA packages. This pinout i; The datasheet does not assign KiCad ERC types. The types here are my judgment: IP+/IP- as passive, O; Pin descriptions for VCC, VIOUT, VREF, VOC, OCF and GAIN_SEL pull limits from the 3.3 V electrical t"
],
"pages_sent": 40,
"cost_usd": 0.2493,
"at": "2026-11-11T00:05:58"
},
"datasheet": {
"url": "https://datasheet.lcsc.com/datasheet/pdf/25d49d471aebfea6a3521341f31b275b.pdf",
"pages": 40,
"sha256": "94154d3a98f3b160",
"source_tier": "lcsc"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 16,
"described": 16,
"cites_pages": true,
"refuses_to_fabricate": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "acs37002kmabtr-050b3.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
10.3,
10.3,
2.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "159663ceb2b4996b1b89d3111e4a355fc27de3e24d3570f50e5ed9086e0d73af",
"checked": "2026-11-11",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
},
{
"file": "acs37002kmabtr-050b3-etched.step",
"role": "eda",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
10.3,
10.3,
2.75
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "fdaf31b3e2053788495b5dfb254da9384bbd11a49b90a0a96f80879e086a0976",
"checked": "2026-11-11",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "Allegro MicroSystems, LLC",
"Package": "SOIC-16-300mil",
"Category": "Sensors",
"Pins": "16"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "94154d3a98f3b16074c1b63571da41515df0f6325103db5f2f993d2d91db39ce",
"rows": [
{
"name": "Forward Supply Voltage",
"symbol": "VCC",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 6.5,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Reverse Supply Voltage",
"symbol": "VRCC",
"kind": "absolute_maximum",
"unit": "V",
"min": -0.5,
"typ": null,
"max": null,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Forward Output Voltage",
"symbol": "VFIOUT",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 6.5,
"conditions": "Applies to VIOUT, VOCF, and VREF; (VCC + 0.7) ≤ 6.5 V",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Reverse Output Voltage",
"symbol": "VRIOUT",
"kind": "absolute_maximum",
"unit": "V",
"min": -0.5,
"typ": null,
"max": null,
"conditions": "Applies to VIOUT, VOCF, and VREF",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Forward Input Voltage",
"symbol": "VOI",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 6.5,
"conditions": "Applies to GAIN_SEL0, GAIN_SEL1, and VOC; (VCC + 0.7) ≤ 6.5 V",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Reverse Input Voltage",
"symbol": "VRI",
"kind": "absolute_maximum",
"unit": "V",
"min": -0.5,
"typ": null,
"max": null,
"conditions": "Applies to GAIN_SEL0, GAIN_SEL1, and VOC",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Operating Ambient Temperature",
"symbol": "TA",
"kind": "absolute_maximum",
"unit": "°C",
"min": -40,
"typ": null,
"max": 150,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Storage Temperature",
"symbol": "Tstg",
"kind": "absolute_maximum",
"unit": "°C",
"min": -65,
"typ": null,
"max": 165,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Maximum Junction Temperature",
"symbol": "TJ(max)",
"kind": "absolute_maximum",
"unit": "°C",
"min": null,
"typ": null,
"max": 165,
"conditions": "",
"source_page": 4,
"source": "datasheet"
},
{
"name": "Supply Voltage (3.3 V devices)",
"symbol": "VCC",
"kind": "recommended_operating",
"unit": "V",
"min": 3.15,
"typ": 3.3,
"max": 3.6,
"conditions": "3.3 V devices only",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Supply Current",
"symbol": "ICC",
"kind": "electrical",
"unit": "mA",
"min": null,
"typ": 12,
"max": 15,
"conditions": "No load on VIOUT or VREF; VCC = 3.3 V",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Output Resistive Load",
"symbol": "RL",
"kind": "recommended_operating",
"unit": "kΩ",
"min": 10,
"typ": null,
"max": null,
"conditions": "VIOUT to GND, VIOUT to VCC",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Output Capacitive Load",
"symbol": "CL",
"kind": "recommended_operating",
"unit": "nF",
"min": null,
"typ": 1,
"max": 6,
"conditions": "VIOUT to GND",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Reference Resistive Load",
"symbol": "RVREF",
"kind": "recommended_operating",
"unit": "kΩ",
"min": 10,
"typ": 62.7,
"max": null,
"conditions": "VREF to GND (recommended to supply VOC); VREF to VCC",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Reference Capacitive Load",
"symbol": "CVREF",
"kind": "recommended_operating",
"unit": "nF",
"min": null,
"typ": null,
"max": 6,
"conditions": "VREF to GND",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Fault Pull-Up Resistance",
"symbol": "RPU",
"kind": "recommended_operating",
"unit": "kΩ",
"min": 4.7,
"typ": null,
"max": 500,
"conditions": "",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Power-On Reset Voltage (rising)",
"symbol": "VPOR(H)",
"kind": "electrical",
"unit": "V",
"min": 2.6,
"typ": 2.9,
"max": 3.1,
"conditions": "VCC rising [1]",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Power-On Reset Voltage (falling)",
"symbol": "VPOR(L)",
"kind": "electrical",
"unit": "V",
"min": 2.2,
"typ": 2.5,
"max": 2.8,
"conditions": "VCC falling [1]",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Power-On Time",
"symbol": "tPOD",
"kind": "timing",
"unit": "µs",
"min": 100,
"typ": null,
"max": null,
"conditions": "Time from VCC rising ≥ VUVD(DIS) after a POR event until power-on; VREF, OCF, VIOUT",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Overvoltage Detection Threshold (rising)",
"symbol": "VOVD(H)",
"kind": "electrical",
"unit": "V",
"min": 6.1,
"typ": 6.3,
"max": 6.8,
"conditions": "TA = 25°C, VCC rising [1]",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Overvoltage Detection Threshold (falling)",
"symbol": "VOVD(L)",
"kind": "electrical",
"unit": "V",
"min": 5.6,
"typ": 5.8,
"max": 6.1,
"conditions": "TA = 25°C, VCC falling [1]",
"source_page": 7,
"source": "datasheet"
},
{
"name": "Saturation Voltage Low",
"symbol": "VSAT(L)",
"kind": "electrical",
"unit": "V",
"min": null,
"typ": null,
"max": 0.15,
"conditions": "RL = 10 kΩ to VCC",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Output Voltage Operating Range (3.3 V linear)",
"symbol": "VOOR",
"kind": "recommended_operating",
"unit": "V",
"min": 0.3,
"typ": null,
"max": 3,
"conditions": "3.3 V linear operating range",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Output Drive",
"symbol": "IOUT",
"kind": "electrical",
"unit": "mA",
"min": 4.8,
"typ": null,
"max": null,
"conditions": "",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Rise Time",
"symbol": "tR",
"kind": "timing",
"unit": "µs",
"min": null,
"typ": 0.7,
"max": 2.5,
"conditions": "TA = 25°C, CL = 5.7 nF, 10%-90% of 1 V output swing",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Propagation Delay",
"symbol": "tpd",
"kind": "timing",
"unit": "µs",
"min": null,
"typ": 0.7,
"max": 2,
"conditions": "TA = 25°C, CL = 5.7 nF, 20% input to 20% of 1 V output swing",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Nonlinearity",
"symbol": "ELIN",
"kind": "tolerance",
"unit": "%",
"min": -0.75,
"typ": null,
"max": 0.75,
"conditions": "",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Power Supply Offset Error",
"symbol": "VOE(PS)",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": null,
"max": 10,
"conditions": "VCC @ VCC(MIN) or VCC(MAX)",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Power Supply Sensitivity Error",
"symbol": "ESENS(PS)",
"kind": "tolerance",
"unit": "%",
"min": -1.5,
"typ": null,
"max": 1.5,
"conditions": "VCC @ VCC(MIN) or VCC(MAX)",
"source_page": 8,
"source": "datasheet"
},
{
"name": "Zero Current Reference Voltage (bidirectional, 3.3 V)",
"symbol": "VREF(BI)",
"kind": "electrical",
"unit": "V",
"min": 1.64,
"typ": 1.65,
"max": 1.66,
"conditions": "Bidirectional; VCC = 3.3 V",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Reference Slew Rate",
"symbol": "SRREF",
"kind": "timing",
"unit": "V/µs",
"min": 0.8,
"typ": null,
"max": null,
"conditions": "CVREF = 0 nF, RVREF = 0 Ω",
"source_page": 9,
"source": "datasheet"
},
{
"name": "OCF On Voltage",
"symbol": "VFAULT-ON",
"kind": "electrical",
"unit": "V",
"min": null,
"typ": 0.07,
"max": 0.4,
"conditions": "RPU = 4.7 kΩ, under fault condition",
"source_page": 9,
"source": "datasheet"
},
{
"name": "OCF Sink Current (fault assertion)",
"symbol": "IOCF(SNK)",
"kind": "electrical",
"unit": "mA",
"min": 0.01,
"typ": null,
"max": 1.1,
"conditions": "Fault Assertion",
"source_page": 9,
"source": "datasheet"
},
{
"name": "VOC Operating Voltage Range (3.3 V)",
"symbol": "VVOC",
"kind": "recommended_operating",
"unit": "V",
"min": 0.33,
"typ": null,
"max": 1.32,
"conditions": "VCC = 3.3 V",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Fault Error",
"symbol": "EOCF",
"kind": "tolerance",
"unit": "%IOCF-OP",
"min": -10,
"typ": null,
"max": 10,
"conditions": "",
"source_page": 9,
"source": "datasheet"
},
{
"name": "OCF Reaction Time",
"symbol": "tOCF-R",
"kind": "timing",
"unit": "µs",
"min": null,
"typ": 1,
"max": 1.5,
"conditions": "Time from IOCF-OP, with a 1.2 × IOCF-OP until fault asserts",
"source_page": 9,
"source": "datasheet"
},
{
"name": "OCF Mask Time",
"symbol": "tOCF-MASK",
"kind": "timing",
"unit": "µs",
"min": 0,
"typ": 0,
"max": 3,
"conditions": "Time IOCF-OP must be present after tOCF-R for fault assertion [3]",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Gain Select Logic Input Voltage (high, 3.3 V)",
"symbol": "VH(SEL)",
"kind": "electrical",
"unit": "V",
"min": 2.25,
"typ": null,
"max": null,
"conditions": "VCC = 3.3 V",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Gain Select Logic Input Voltage (low)",
"symbol": "VL(SEL)",
"kind": "electrical",
"unit": "V",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "",
"source_page": 9,
"source": "datasheet"
},
{
"name": "Current Sensing Range",
"symbol": "IPR",
"kind": "electrical",
"unit": "A",
"min": -50,
"typ": null,
"max": 50,
"conditions": "Gain Sel 00",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Current Sensing Range",
"symbol": "IPR",
"kind": "electrical",
"unit": "A",
"min": -40,
"typ": null,
"max": 40,
"conditions": "Gain Sel 01",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Current Sensing Range",
"symbol": "IPR",
"kind": "electrical",
"unit": "A",
"min": -33.3,
"typ": null,
"max": 33.3,
"conditions": "Gain Sel 10",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Current Sensing Range",
"symbol": "IPR",
"kind": "electrical",
"unit": "A",
"min": -66.7,
"typ": null,
"max": 66.7,
"conditions": "Gain Sel 11",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Overcurrent Fault Operating Range",
"symbol": "IOCF-OR",
"kind": "electrical",
"unit": "%FS",
"min": 50,
"typ": 100,
"max": 200,
"conditions": "Typ. = factory-programmed default, FS = Full-Scale",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Total Error",
"symbol": "ETOT",
"kind": "tolerance",
"unit": "%",
"min": -1.75,
"typ": -0.5,
"max": 1.75,
"conditions": "IP = IPR(max)",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Sensitivity Error",
"symbol": "ESENS",
"kind": "tolerance",
"unit": "%",
"min": -1,
"typ": -0.3,
"max": 1,
"conditions": "IP = IPR(max), TA = 25°C to 125°C, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Zero Current Reference Error (25°C to 125°C)",
"symbol": "VRE",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -2,
"max": 10,
"conditions": "VREFactual – VREFideal, IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Zero Current Reference Error (-40°C to 25°C)",
"symbol": "VRE",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -1,
"max": 10,
"conditions": "VREFactual – VREFideal, IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Offset Error (25°C to 125°C)",
"symbol": "VOE",
"kind": "tolerance",
"unit": "mV",
"min": -8,
"typ": null,
"max": 8,
"conditions": "VIOUT(Q) – VREF, IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Offset Error (-40°C to 25°C)",
"symbol": "VOE",
"kind": "tolerance",
"unit": "mV",
"min": -8,
"typ": -1,
"max": 8,
"conditions": "VIOUT(Q) – VREF, IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "QVO Error (25°C to 125°C)",
"symbol": "VQE",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -3,
"max": 10,
"conditions": "VIOUT(Q), IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "QVO Error (-40°C to 25°C)",
"symbol": "VQE",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": null,
"max": 10,
"conditions": "VIOUT(Q), IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Total Error Including Lifetime Drift",
"symbol": "ETOT_LTD",
"kind": "tolerance",
"unit": "%",
"min": -3.4,
"typ": -1.4,
"max": 3.4,
"conditions": "IP = IPR(max)",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Sensitivity Error Including Lifetime Drift",
"symbol": "ESENS_LTD",
"kind": "tolerance",
"unit": "%",
"min": -3.2,
"typ": -1.3,
"max": 3.2,
"conditions": "IP = IPR(max), TA = 25°C to 125°C or –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Zero Current Reference Error Including Lifetime Drift (25°C to 125°C)",
"symbol": "VRE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -3,
"max": 10,
"conditions": "VREFactual – VREFideal, IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Zero Current Reference Error Including Lifetime Drift (-40°C to 25°C)",
"symbol": "VRE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -2,
"max": 10,
"conditions": "VREFactual – VREFideal, IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Offset Error Including Lifetime Drift (25°C to 125°C)",
"symbol": "VOE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": -2,
"max": 10,
"conditions": "VIOUT(Q) – VREF, IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "Offset Error Including Lifetime Drift (-40°C to 25°C)",
"symbol": "VOE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": null,
"max": 10,
"conditions": "VIOUT(Q) – VREF, IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "QVO Error Including Lifetime Drift (25°C to 125°C)",
"symbol": "VQE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -14,
"typ": -4,
"max": 14,
"conditions": "VIOUT(Q), IP = 0 A, TA = 25°C to 125°C",
"source_page": 19,
"source": "datasheet"
},
{
"name": "QVO Error Including Lifetime Drift (-40°C to 25°C)",
"symbol": "VQE_LTD",
"kind": "tolerance",
"unit": "mV",
"min": -10,
"typ": null,
"max": 10,
"conditions": "VIOUT(Q), IP = 0 A, TA = –40°C to 25°C",
"source_page": 19,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"acs37002kmabtr-050b3"
],
"discovery_pitch": "ACS37002KMABTR-050B3 (Allegro MicroSystems, LLC) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"acs37002kmabtr-050b3.kicad_sym",
"acs37002kmabtr-050b3.kicad_mod",
"acs37002kmabtr-050b3.glb",
"acs37002kmabtr-050b3.step",
"acs37002kmabtr-050b3.lbr",
"docs/hero.png",
"docs/acs37002kmabtr-050b3-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"acs37002kmabtr-050b3-hero.glb",
"acs37002kmabtr-050b3-hero.overlay.json",
"acs37002kmabtr-050b3-etched.glb"
],
"visibility": {
"public": true
}
}