main
Ray
Set visibility: public
c4b9231
123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387
{
"schema_version": 1,
"type": "component",
"slug": "ac0603fr-104k7l",
"title": "AC0603FR-104K7L",
"brief": "YAGEO Resistors, 0603 (1608 metric). Pinout settled in review by an AI reviewer against the manufacturer's datasheet, KiCad symbol/footprint/3D.",
"version": "0.1.0",
"license": "CC-BY-SA-4.0",
"tags": [
"component",
"resistors",
"ac0603fr-104k7l",
"factory-2.0.0",
"extractor-text"
],
"component": {
"mpn": "AC0603FR-104K7L",
"manufacturer": "YAGEO",
"package": "0603 (1608 metric)",
"pin_count": 2,
"category": "Resistors",
"subcategory": "Resistors",
"datasheet": "https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L",
"parts": {
"symbol": "ac0603fr-104k7l.kicad_sym",
"footprint": "ac0603fr-104k7l.kicad_mod",
"model_3d": "ac0603fr-104k7l-hero.glb",
"model_3d_step": "ac0603fr-104k7l.step",
"lbr": "ac0603fr-104k7l.lbr",
"model_3d_plain": "ac0603fr-104k7l.glb"
},
"distributor_links": {
"digikey": "13-AC0603FR-104K7LCT-ND",
"mouser": "603-AC0603FR-104K7L"
},
"distributor_check": {
"checked_at": "2026-11-27T09:41:41Z",
"source": "Component Ocean /api/assign-pns",
"digikey": {
"pn": "13-AC0603FR-104K7LCT-ND",
"status": "found"
},
"mouser": {
"pn": "603-AC0603FR-104K7L",
"status": "found"
}
},
"pins": [
{
"number": "1",
"name": "1",
"type": "passive",
"description": "Terminal 1 of an unpolarised resistor; either orientation."
},
{
"number": "2",
"name": "2",
"type": "passive",
"description": "Terminal 2 of an unpolarised resistor; either orientation."
}
],
"provenance": {
"extractor": "review decision",
"pin_review": {
"by": "ray (review: wrong document? family sheet without the full MPN; task master ruling 2026-11-27 accepts reel code 10)",
"kind": "review",
"at": "2026-11-27T09:41:25Z"
},
"datasheet": {
"url": "https://yageogroup.com/content/datasheet/asset/file/PYU-AC_51_ROHS_L",
"pages": 13,
"sha256": "dc6648aefe53a866",
"source_tier": "mfr",
"citation": "YAGEO datasheet"
},
"cad": "KiCad official (CC-BY-SA 4.0)",
"pins": {
"total": 2,
"described": 2,
"cites_pages": true,
"refuses_to_fabricate": true
},
"model_origin": {
"blob_sha256": "1875571c326d0d9e96f36b4efeb8094068ef7619f0a449c781caf0b49c2e5861",
"file": "R_0603_1608Metric.step",
"package_key": "Resistor_SMD:R_0603_1608Metric",
"source": "reef standard-3d",
"via": "reef standard-3d",
"page_step_identical": true
}
},
"viewers": {
"symbol": "viewers/symbol.html",
"footprint": "viewers/footprint.html"
},
"models_3d": [
{
"file": "ac0603fr-104k7l.step",
"role": "plain",
"up": "Z",
"units": "mm",
"origin": "footprint origin = pad-pattern centre",
"seat": "z = 0",
"extents_mm": [
1.6,
0.8,
0.45
],
"zmin_mm": 0,
"centre_offset_mm": 0,
"footprint_binding": "identity",
"sha256": "1875571c326d0d9e96f36b4efeb8094068ef7619f0a449c781caf0b49c2e5861",
"checked": "2026-11-27",
"checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
}
]
},
"metadata": {
"specs": {
"Manufacturer": "YAGEO",
"Package": "0603 (1608 metric)",
"Category": "Resistors",
"Pins": "2"
},
"characteristics": {
"version": 1,
"source": "datasheet",
"datasheet_sha256": "dc6648aefe53a86640b032859cd1f6c2ad1e32b74cf0f795b41a0c3a654ed70c",
"rows": [
{
"name": "Resistance tolerance",
"symbol": "",
"kind": "tolerance",
"unit": "%",
"min": -1,
"typ": null,
"max": 1,
"conditions": "F = ±1% tolerance code in part number",
"source_page": 2,
"source": "datasheet"
},
{
"name": "Temperature coefficient of resistance",
"symbol": "TCR",
"kind": "temperature_coefficient",
"unit": "ppm/°C",
"min": -100,
"typ": null,
"max": 100,
"conditions": "AC0603 1/10 W, 10Ω ≤ R ≤ 10MΩ, base spec (blank TCR code)",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Operating temperature range",
"symbol": "TA",
"kind": "recommended_operating",
"unit": "°C",
"min": -55,
"typ": null,
"max": 155,
"conditions": "AC0603 1/10 W",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Max. working voltage",
"symbol": "",
"kind": "recommended_operating",
"unit": "V",
"min": null,
"typ": null,
"max": 75,
"conditions": "AC0603 1/10 W, or rated voltage formula result whichever is less",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Max. overload voltage",
"symbol": "",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 150,
"conditions": "AC0603 1/10 W, short time overload 2.5x rated voltage or max overload voltage whichever is less for 5 sec",
"source_page": 5,
"source": "datasheet"
},
{
"name": "Dielectric withstanding voltage",
"symbol": "",
"kind": "absolute_maximum",
"unit": "V",
"min": null,
"typ": null,
"max": 150,
"conditions": "AC0603 1/10 W",
"source_page": 5,
"source": "datasheet"
},
{
"name": "High temperature exposure resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "1,000 hours at TA = 155 °C, unpowered; ± (1.0%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Moisture resistance resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "MIL-STD-202 Method 106; ± (0.5%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Biased humidity resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "1,000 hours; 85 °C / 85% RH, 10% of operating power; ± (1.0%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Operational life resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "1,000 hours at 125 °C, derated voltage applied; ± (1.0%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Resistance to soldering heat resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "Lead-free solder, 260± 5 °C, 10± 1 seconds immersion; ± (0.5%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Thermal shock resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 0.5,
"conditions": "-55/+125 °C, 300 cycles; ± (0.5%+0.05Ω) for D/F tol",
"source_page": 10,
"source": "datasheet"
},
{
"name": "ESD human body model resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 3,
"conditions": "AEC-Q200 Test 17, HBM 1 pos. + 1 neg. discharges, 0402/0603: 1KV; ± (3.0%+0.05Ω)",
"source_page": 10,
"source": "datasheet"
},
{
"name": "ESD human body model voltage",
"symbol": "",
"kind": "absolute_maximum",
"unit": "KV",
"min": null,
"typ": null,
"max": 1,
"conditions": "AEC-Q200 Test 17, Human Body Model, 0402/0603",
"source_page": 10,
"source": "datasheet"
},
{
"name": "Board flex resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "Bending for 0603/0805: 3 mm; ± (1.0%+0.05Ω)",
"source_page": 11,
"source": "datasheet"
},
{
"name": "Short time overload resistance change",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "2.5 times rated voltage or maximum overload voltage whichever is less for 5 sec at room temperature; ± (1.0%+0.05Ω) for D/F tol",
"source_page": 11,
"source": "datasheet"
},
{
"name": "Sulfur resistance change (FOS)",
"symbol": "",
"kind": "electrical",
"unit": "%",
"min": null,
"typ": null,
"max": 1,
"conditions": "500 hours, 60± 2°C, unpowered; ± (1.0%+0.05Ω)",
"source_page": 11,
"source": "datasheet"
},
{
"name": "Rated power",
"symbol": "P",
"kind": "electrical",
"unit": "W",
"min": null,
"typ": 0.1,
"max": null,
"conditions": "AC0603 1/10 W rated at 70 °C",
"source_page": 9,
"source": "datasheet"
}
]
}
},
"variants": [],
"sections": [
"hero",
"viewers",
"readme",
"breadcrumbs",
"info"
],
"discovery_triggers": [
"ac0603fr-104k7l"
],
"discovery_pitch": "AC0603FR-104K7L (YAGEO) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
"author": {
"name": "Ray"
},
"dependencies": {},
"hero": {
"type": "image",
"path": "docs/hero.png"
},
"files": [
"page.json",
"README.md",
"ac0603fr-104k7l.kicad_sym",
"ac0603fr-104k7l.kicad_mod",
"ac0603fr-104k7l.glb",
"ac0603fr-104k7l.step",
"ac0603fr-104k7l.lbr",
"docs/hero.png",
"docs/ac0603fr-104k7l-datasheet.pdf",
"viewers/symbol.html",
"viewers/footprint.html",
"ac0603fr-104k7l-hero.glb",
"ac0603fr-104k7l-hero.overlay.json"
],
"visibility": {