← Commit history

1812l400-24gr: factory component page (tier=lcsc)

Ray ·824ec24245 · ·parent c1db0db
1 file changed +143−30
page.json+143−30
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "1812l400-24gr",+  "title": "1812L400/24GR",+  "brief": "LUTE Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "LUTE Resettable Fuses, 1812. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "circuit protection",@@ -10,26 +13,6 @@     "factory-2.0.0",     "extractor-text"   ],-  "dependencies": {},-  "hero": {-    "type": "image",-    "path": "docs/hero.png"-  },-  "files": [-    "page.json",-    "README.md",-    "1812l400-24gr.kicad_sym",-    "1812l400-24gr.kicad_mod",-    "1812l400-24gr.glb",-    "1812l400-24gr.step",-    "1812l400-24gr.lbr",-    "docs/hero.png",-    "docs/1812l400-24gr-datasheet.pdf",-    "viewers/symbol.html",-    "viewers/footprint.html",-    "1812l400-24gr-hero.glb",-    "1812l400-24gr-hero.overlay.json"-  ],   "component": {     "mpn": "1812L400/24GR",     "manufacturer": "LUTE",@@ -104,7 +87,7 @@         "family": "_1806_",         "height_mm": 0.9,         "height_basis": "family nominal (no datasheet A read)",-        "standoff_mm": 0+        "standoff_mm": 0.0       },       "pins": {         "total": 2,@@ -130,8 +113,8 @@           3.22,           0.9         ],-        "zmin_mm": 0,-        "centre_offset_mm": 0,+        "zmin_mm": 0.0,+        "centre_offset_mm": 0.0,         "footprint_binding": "identity",         "sha256": "a38f240e5d802ebe42a5b8cbe2be315ef9fe7a6e66d7164fcf2930a457f0bd60",         "checked": "2026-11-16",@@ -139,9 +122,139 @@       }     ]   },-  "visibility": "private",-  "org": "adom",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "1812",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "4a6d47229be2750c22771f7456a9f7eaa6d210ead6f58e5c8b5b719a16fe9413",+      "rows": [+        {+          "name": "Hold current",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "25℃ still air",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "at rated voltage (V max)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Initial resistance (un-soldered)",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.005,+          "typ": null,+          "max": null,+          "conditions": "minimum resistance in initial (un-soldered) state",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Time to trip",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "at 10.00 A, 25℃",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "absolute_maximum",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped state",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Typical tripped power dissipation",+          "symbol": "P d typ.",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 2,+          "max": null,+          "conditions": "tripped state, 25℃ still air",+          "source_page": 4,+          "source": "datasheet"+        }+      ]+    }+  },+  "variants": [],+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "1812l400"+  ],+  "discovery_pitch": "1812L400 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",   "author": {-    "name": "Ray"-  }-}\ No newline at end of file+    "name": "Ray",+    "email": "[email protected]"+  },+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "1812l400-24gr.kicad_sym",+    "1812l400-24gr.kicad_mod",+    "1812l400-24gr.glb",+    "1812l400-24gr.step",+    "1812l400-24gr.lbr",+    "docs/hero.png",+    "docs/1812l400-24gr-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "1812l400-24gr-hero.glb",+    "1812l400-24gr-hero.overlay.json"+  ]+}