main
Ray Set visibility: public 05fb6c9
{
  "schema_version": 1,
  "type": "component",
  "slug": "1206l005-110wr",
  "title": "1206L005/110WR",
  "brief": "LUTE Resettable Fuses, 1206. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
  "version": "0.1.0",
  "license": "CC-BY-SA-4.0",
  "tags": [
    "component",
    "circuit protection",
    "1206l005",
    "factory-2.0.0",
    "extractor-text"
  ],
  "component": {
    "mpn": "1206L005/110WR",
    "manufacturer": "LUTE",
    "package": "1206",
    "pin_count": 2,
    "category": "Circuit Protection",
    "subcategory": "Resettable Fuses",
    "datasheet": "https://datasheet.lcsc.com/datasheet/pdf/40c7d406381be5f2379f60ca1e0129f4.pdf",
    "parts": {
      "symbol": "1206l005-110wr.kicad_sym",
      "footprint": "1206l005-110wr.kicad_mod",
      "model_3d": "1206l005-110wr-hero.glb",
      "model_3d_step": "1206l005-110wr.step",
      "lbr": "1206l005-110wr.lbr",
      "model_3d_plain": "1206l005-110wr.glb"
    },
    "distributor_links": {
      "lcsc": "C46422913"
    },
    "distributor_check": {
      "checked_at": "2026-11-20T23:03:00Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": null,
        "status": "deferred",
        "error": "shared DigiKey quota guard: 934 calls left today"
      },
      "mouser": {
        "pn": null,
        "status": "no match"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "1",
        "type": "passive",
        "description": "Terminal 1 of an unpolarised fuse; either orientation."
      },
      {
        "number": "2",
        "name": "2",
        "type": "passive",
        "description": "Terminal 2 of an unpolarised fuse; either orientation."
      }
    ],
    "provenance": {
      "extractor": "extract_pins",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins",
        "primary_model": "two-terminal convention",
        "primary_mode": "convention",
        "consensus_model": null,
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "vision extraction: provenance cannot be text-verified; needs consensus"
        ],
        "pages_sent": 13,
        "cost_usd": 0.0038,
        "at": "2026-11-20T23:02:53"
      },
      "datasheet": {
        "url": "https://datasheet.lcsc.com/datasheet/pdf/40c7d406381be5f2379f60ca1e0129f4.pdf",
        "pages": 13,
        "sha256": "7778e054e36d6416",
        "source_tier": "lcsc",
        "citation": "LUTE datasheet, copy hosted by LCSC"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 2,
        "described": 2,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "models_3d": [
      {
        "file": "1206l005-110wr.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          3.2,
          1.6,
          0.55
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "5e6dcbe286696143d35a8ea37d91eef4b54ff3d1bd7c2c2b4dedda83d3f8e203",
        "checked": "2026-11-20",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ],
    "package_dims": {
      "package_code": "1206",
      "source_page": 5,
      "D": {
        "nom_mm": 3.3,
        "range_mm": [
          3,
          3.6
        ]
      },
      "E1": {
        "nom_mm": 1.7,
        "range_mm": [
          1.5,
          1.9
        ]
      },
      "A": {
        "nom_mm": 0.9,
        "range_mm": [
          0.6,
          1.2
        ]
      },
      "source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",
      "model_check": {
        "file": "1206l005-110wr.step",
        "verdict": "PASS",
        "reasons": [
          "height within the datasheet's package drawing"
        ],
        "by": "factory/package_fit.py"
      }
    }
  },
  "metadata": {
    "specs": {
      "Manufacturer": "LUTE",
      "Package": "1206",
      "Category": "Circuit Protection",
      "Pins": "2"
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "7778e054e36d6416d593f2621a0419546a3e10bdcb98428b0f991803815d872a",
      "rows": [
        {
          "name": "Hold current (max current without tripping)",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.05,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; 25℃ still air",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Trip current (min current that trips the device)",
          "symbol": "I trip",
          "kind": "electrical",
          "unit": "A",
          "min": 0.15,
          "typ": null,
          "max": null,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; 25℃ still air",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Minimum resistance, initial un-soldered state",
          "symbol": "R min",
          "kind": "electrical",
          "unit": "Ω",
          "min": 3.6,
          "typ": null,
          "max": null,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; initial un-soldered state",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum resistance after trip or reflow",
          "symbol": "R 1max",
          "kind": "electrical",
          "unit": "Ω",
          "min": null,
          "typ": null,
          "max": 50,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; 25℃, one hour after tripping or reflow 260℃ for 20 s",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum voltage withstand at rated current",
          "symbol": "V max",
          "kind": "absolute_maximum",
          "unit": "Vdc",
          "min": null,
          "typ": null,
          "max": 30,
          "conditions": "1206L005/30NR at rated current I max",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum voltage withstand at rated current",
          "symbol": "V max",
          "kind": "absolute_maximum",
          "unit": "Vdc",
          "min": null,
          "typ": null,
          "max": 60,
          "conditions": "1206L005/60NR at rated current I max",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum voltage withstand at rated current",
          "symbol": "V max",
          "kind": "absolute_maximum",
          "unit": "Vdc",
          "min": null,
          "typ": null,
          "max": 72,
          "conditions": "1206L005/72NR at rated current I max",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum voltage withstand at rated current",
          "symbol": "V max",
          "kind": "absolute_maximum",
          "unit": "Vdc",
          "min": null,
          "typ": null,
          "max": 85,
          "conditions": "1206L005/85NR at rated current I max",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum fault current withstand at rated voltage",
          "symbol": "I max",
          "kind": "absolute_maximum",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 40,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; at rated voltage V max",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum time to trip",
          "symbol": "",
          "kind": "electrical",
          "unit": "s",
          "min": null,
          "typ": null,
          "max": 1.5,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; at 0.25 A",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Power dissipated in tripped state",
          "symbol": "P d",
          "kind": "electrical",
          "unit": "W",
          "min": null,
          "typ": 0.7,
          "max": null,
          "conditions": "1206L005/30NR, /60NR, /72NR, /85NR; tripped state, 25℃ still air",
          "source_page": 1,
          "source": "datasheet"
        },
        {
          "name": "Maximum surface temperature in tripped state",
          "symbol": "",
          "kind": "thermal",
          "unit": "℃",
          "min": null,
          "typ": null,
          "max": 125,
          "conditions": "device in tripped state",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Ambient operating temperature range",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "℃",
          "min": -40,
          "typ": null,
          "max": 85,
          "conditions": "ambient operating conditions",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Storage temperature of packaged product",
          "symbol": "",
          "kind": "recommended_operating",
          "unit": "℃",
          "min": 0,
          "typ": null,
          "max": 30,
          "conditions": "storage condition, 30%-60%RH",
          "source_page": 10,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.074,
          "conditions": "1206L005 at ambient -40℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.066,
          "conditions": "1206L005 at ambient -20℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.056,
          "conditions": "1206L005 at ambient 0℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.05,
          "conditions": "1206L005 at ambient 25℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.042,
          "conditions": "1206L005 at ambient 40℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.037,
          "conditions": "1206L005 at ambient 50℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.035,
          "conditions": "1206L005 at ambient 60℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.03,
          "conditions": "1206L005 at ambient 70℃",
          "source_page": 8,
          "source": "datasheet"
        },
        {
          "name": "Hold current derated at ambient temperature",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.027,
          "conditions": "1206L005 at ambient 85℃",
          "source_page": 8,
          "source": "datasheet"
        }
      ]
    }
  },
  "variants": [],
  "sections": [
    "hero",
    "viewers",
    "readme",
    "breadcrumbs",
    "info"
  ],
  "discovery_triggers": [
    "1206l005"
  ],
  "discovery_pitch": "1206L005 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "author": {
    "name": "Ray"
  },
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "1206l005-110wr.kicad_sym",
    "1206l005-110wr.kicad_mod",
    "1206l005-110wr.glb",
    "1206l005-110wr.step",
    "1206l005-110wr.lbr",
    "docs/hero.png",
    "docs/1206l005-110wr-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "1206l005-110wr-hero.glb",
    "1206l005-110wr-hero.overlay.json"
  ],
  "visibility": {
    "public": true
  }
}