main
Ray Publish 0.1.0 944d05b 2d ago

0805L200SL6ARG

LUTE · Resettable Fuses · 0805

0805L200SL6ARG from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model); symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive One terminal of the non-polarized resettable PPTC; rated 2.00 A hold, 4.00 A trip, 6.0 Vdc max, 50 A max fault current.
2 2 passive Other terminal of the non-polarized resettable PPTC; the two end terminations are interchangeable, with a recommended pad of 1.0±0.1 mm wide by 1.50±0.1 mm long and a 1.20±0.1 mm gap.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (max device current without tripping) I hold 2 A 25℃ still air 2
Trip current (min current at which device trips) I trip 4 A 25℃ still air 2
Maximum voltage rating V max 6 Vdc at rated current (I max) 2
Maximum fault current rating I max 50 A at rated voltage (V max) 2
Typical power dissipated in tripped state P d 1.2 W 25℃ still air, tripped state 2
Maximum time to trip T trip 5 s at 8.00 A 2
Minimum initial resistance (un-soldered) R min 0.008 Ω initial (un-soldered) state 2
Maximum resistance after trip or reflow R 1max 0.05 Ω 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 sec 2
Resistance change, passive aging -5 5 % +85°C, 1000 hours (typical) 4
Resistance change, humidity aging -5 5 % +85°C, 85% R.H., 168 hours (typical) 4
Resistance change, thermal shock -33 33 % +85°C to -40°C, 20 times (typical) 4
Ambient operating temperature -40 85 ℃ Ambient operating conditions 4
Maximum surface temperature in tripped state 125 ℃ device in tripped state 4
Ambient-temperature hold current derating, -40℃ I hold 2.69 A ambient -40℃; table entry 0805L200SLG (same device, G suffix) 5
Ambient-temperature hold current derating, -20℃ I hold 2.34 A ambient -20℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 0℃ I hold 2.17 A ambient 0℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 25℃ I hold 2 A ambient 25℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 40℃ I hold 1.66 A ambient 40℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 50℃ I hold 1.49 A ambient 50℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 60℃ I hold 1.37 A ambient 60℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 70℃ I hold 1.14 A ambient 70℃; table entry 0805L200SLG 5
Ambient-temperature hold current derating, 85℃ I hold 0.8 A ambient 85℃; table entry 0805L200SLG 5

CAD (KiCad official)

  • Symbol: 0805L200SL6ARG
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)
  • 3D model files: 0805l200sl6arg-etched.step / 0805l200sl6arg-etched.glb carry the MPN laser-etched on the die in a toggleable Adom.LaserEtch group (Fusion-ready); 0805l200sl6arg.step / 0805l200sl6arg.glb are the bare package body.

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet (9 pp, sha256 dbfc10868fd31aa6, retrieved 2026-10-18, tier: lcsc)
  • Extractor: parts-factory 2.0.0 / extract_pins 0.3, primary claude-sonnet-5-5 (text+vision), consensus claude-opus-5-5 (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF