LUTE · Resettable Fuses · 0805

0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (maximum current without tripping, 25℃ still air) I hold 0.75 A 25℃ still air 3
Trip current (minimum current to trip, 25℃ still air) I trip 1.5 A 25℃ still air 3
Maximum fault current withstood without damage I max 40 A at rated voltage (V max) 3
Time to trip (max) at test current 0.2 s test current 8.00 A, 25℃ 3
Minimum initial resistance (un-soldered) R min 0.07 Ω initial un-soldered state, 25℃ 3
Maximum resistance after trip or reflow R 1max 0.385 Ω 25℃, one hour after tripping or reflow soldering of 260℃ for 20 sec 3
Hold current at ambient temperature (derating) I hold 1 A ambient -40℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.9 A ambient -20℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.79 A ambient 0℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.75 A ambient 25℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.63 A ambient 40℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.57 A ambient 50℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.53 A ambient 60℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.41 A ambient 70℃, 0805L075 derating table 6
Hold current at ambient temperature (derating) I hold 0.34 A ambient 85℃, 0805L075 derating table 6
Resistance change after passive aging (typical) -5 5 % +85℃, 1000 hours; typical 5
Resistance change after humidity aging (typical) -5 5 % +85℃, 85% R.H., 168 hours; typical 5
Resistance change after thermal shock (typical) -33 33 % +85℃ to -40℃, 20 times; typical 5
Ambient operating temperature -40 85 ℃ ambient operating conditions 5
Maximum surface temperature in tripped state 125 ℃ device in tripped state 5
Storage temperature 0 30 ℃ storage condition 7
Storage relative humidity 30 60 %RH storage condition 7

CAD (KiCad official)

  • Symbol: 0805L075
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256 5b53a6aa01e0f5ff, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF