main
Ray
Publish 0.1.0
4b81fb5
0805L075
LUTE · Resettable Fuses · 0805
0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current (maximum current without tripping, 25℃ still air) | I hold | 0.75 | A | 25℃ still air | 3 | ||
| Trip current (minimum current to trip, 25℃ still air) | I trip | 1.5 | A | 25℃ still air | 3 | ||
| Maximum fault current withstood without damage | I max | 40 | A | at rated voltage (V max) | 3 | ||
| Time to trip (max) at test current | 0.2 | s | test current 8.00 A, 25℃ | 3 | |||
| Minimum initial resistance (un-soldered) | R min | 0.07 | Ω | initial un-soldered state, 25℃ | 3 | ||
| Maximum resistance after trip or reflow | R 1max | 0.385 | Ω | 25℃, one hour after tripping or reflow soldering of 260℃ for 20 sec | 3 | ||
| Hold current at ambient temperature (derating) | I hold | 1 | A | ambient -40℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.9 | A | ambient -20℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.79 | A | ambient 0℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.75 | A | ambient 25℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.63 | A | ambient 40℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.57 | A | ambient 50℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.53 | A | ambient 60℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.41 | A | ambient 70℃, 0805L075 derating table | 6 | ||
| Hold current at ambient temperature (derating) | I hold | 0.34 | A | ambient 85℃, 0805L075 derating table | 6 | ||
| Resistance change after passive aging (typical) | -5 | 5 | % | +85℃, 1000 hours; typical | 5 | ||
| Resistance change after humidity aging (typical) | -5 | 5 | % | +85℃, 85% R.H., 168 hours; typical | 5 | ||
| Resistance change after thermal shock (typical) | -33 | 33 | % | +85℃ to -40℃, 20 times; typical | 5 | ||
| Ambient operating temperature | -40 | 85 | ℃ | ambient operating conditions | 5 | ||
| Maximum surface temperature in tripped state | 125 | ℃ | device in tripped state | 5 | |||
| Storage temperature | 0 | 30 | ℃ | storage condition | 7 | ||
| Storage relative humidity | 30 | 60 | %RH | storage condition | 7 |
CAD (KiCad official)
- Symbol:
0805L075 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256
5b53a6aa01e0f5ff, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0805L075
**LUTE** · Resettable Fuses · 0805
0805L075 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current (maximum current without tripping, 25℃ still air) | I hold | | | 0.75 | A | 25℃ still air | 3 |
| Trip current (minimum current to trip, 25℃ still air) | I trip | 1.5 | | | A | 25℃ still air | 3 |
| Maximum fault current withstood without damage | I max | | | 40 | A | at rated voltage (V max) | 3 |
| Time to trip (max) at test current | | | | 0.2 | s | test current 8.00 A, 25℃ | 3 |
| Minimum initial resistance (un-soldered) | R min | 0.07 | | | Ω | initial un-soldered state, 25℃ | 3 |
| Maximum resistance after trip or reflow | R 1max | | | 0.385 | Ω | 25℃, one hour after tripping or reflow soldering of 260℃ for 20 sec | 3 |
| Hold current at ambient temperature (derating) | I hold | | | 1 | A | ambient -40℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.9 | A | ambient -20℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.79 | A | ambient 0℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.75 | A | ambient 25℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.63 | A | ambient 40℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.57 | A | ambient 50℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.53 | A | ambient 60℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.41 | A | ambient 70℃, 0805L075 derating table | 6 |
| Hold current at ambient temperature (derating) | I hold | | | 0.34 | A | ambient 85℃, 0805L075 derating table | 6 |
| Resistance change after passive aging (typical) | | -5 | | 5 | % | +85℃, 1000 hours; typical | 5 |
| Resistance change after humidity aging (typical) | | -5 | | 5 | % | +85℃, 85% R.H., 168 hours; typical | 5 |
| Resistance change after thermal shock (typical) | | -33 | | 33 | % | +85℃ to -40℃, 20 times; typical | 5 |
| Ambient operating temperature | | -40 | | 85 | ℃ | ambient operating conditions | 5 |
| Maximum surface temperature in tripped state | | | | 125 | ℃ | device in tripped state | 5 |
| Storage temperature | | 0 | | 30 | ℃ | storage condition | 7 |
| Storage relative humidity | | 30 | | 60 | %RH | storage condition | 7 |
## CAD (KiCad official)
- Symbol: `0805L075`
- Footprint: `Fuse:Fuse_0805_2012Metric`
- 3D model: 0805 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0805l075-24ar-datasheet.pdf) (10 pp, sha256 `5b53a6aa01e0f5ff`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0805l075-24ar-datasheet.pdf)