← Commit history
package.json+324−2@@ -1,6 +1,6 @@ { "slug": "0805l075-16ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -201,5 +201,327 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L075/16AR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",+ "rows": [+ {+ "name": "Trip current (minimum)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 1.5,+ "typ": null,+ "max": null,+ "conditions": "minimum current at which device trips, 25℃ still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current (maximum)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.75,+ "conditions": "maximum current device passes without tripping, 25℃ still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Initial minimum resistance",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.07,+ "typ": null,+ "max": null,+ "conditions": "initial (un-soldered) state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Resistance after trip or reflow (maximum)",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 0.385,+ "conditions": "25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "at rated voltage (V max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Time to trip (maximum)",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "at 8.00 A fault current",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "0805L075/6AR; at rated current (I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 12,+ "conditions": "0805L075/12AR; at rated current (I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 16,+ "conditions": "0805L075/16AR; at rated current (I max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.8,+ "max": null,+ "conditions": "0805L075/6AR; tripped state, 25℃ still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 1,+ "max": null,+ "conditions": "0805L075/16AR; tripped state, 25℃ still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "℃",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped state",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "℃",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition; 30%-60% RH",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85℃, 1000 hours; printed as ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85℃, 85% R.H., 168 hours; printed as ±5% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Resistance change after thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85℃ to -40℃, 20 times; printed as ±33% typical",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.75,+ "conditions": "ambient -40℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.9,+ "conditions": "ambient -20℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.79,+ "conditions": "ambient 0℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.63,+ "conditions": "ambient 40℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.57,+ "conditions": "ambient 50℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.53,+ "conditions": "ambient 60℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.41,+ "conditions": "ambient 70℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient temperature",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.34,+ "conditions": "ambient 85℃; 0805L075 family derating table",+ "source_page": 5,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l075"+ ],+ "discovery_pitch": "0805L075 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l075-16ar", "title": "0805L075/16AR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -535,7 +535,7 @@ "0805l075-16ar-hero.glb", "0805l075-16ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}