main
Ray
Publish 0.1.0
908bccc
0805L050
LUTE · Resettable Fuses · 0805
0805L050 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 1 | A | 25°C still air; minimum current at which device trips (all 0805L050 variants) | 2 | ||
| Minimum resistance, initial (un-soldered) | R min | 0.1 | Ω | Initial un-soldered state (all 0805L050 variants) | 2 | ||
| Maximum voltage, 0805L050/6XR | V max | 6 | Vdc | 0805L050/6XR; maximum voltage device withstands at rated current I max | 2 | ||
| Maximum voltage, 0805L050/12XR | V max | 12 | Vdc | 0805L050/12XR; maximum voltage device withstands at rated current I max | 2 | ||
| Maximum voltage, 0805L050/15XR | V max | 15 | Vdc | 0805L050/15XR; maximum voltage device withstands at rated current I max | 2 | ||
| Maximum voltage, 0805L050/24XR | V max | 24 | Vdc | 0805L050/24XR; maximum voltage device withstands at rated current I max | 2 | ||
| Maximum fault current | I max | 40 | A | All 0805L050 variants; maximum fault current at rated voltage V max | 2 | ||
| Maximum resistance after trip or reflow | R 1max | 0.85 | Ω | 25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s | 2 | ||
| Maximum time to trip | T trip | 0.1 | s | At 8.00 A test current (current column of time-to-trip table) | 2 | ||
| Passive aging resistance change | -5 | 5 | % | +85°C, 1000 hours; typical | 4 | ||
| Humidity aging resistance change | -5 | 5 | % | +85°C, 85% R.H., 168 hours; typical | 4 | ||
| Thermal shock resistance change | -33 | 33 | % | +85°C to -40°C, 20 times; typical | 4 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | Ambient operating conditions | 4 | |
| Maximum surface temperature in tripped state | 125 | °C | Device in tripped state | 4 | |||
| Hold current | I hold | 0.5 | A | 25°C still air; maximum current device passes without tripping (all 0805L050 variants) | 2 | ||
| Typical power in tripped state, 0805L050/6XR | P d | 0.5 | W | 0805L050/6XR; 25°C still air, tripped state | 2 | ||
| Typical power in tripped state, 0805L050/12XR | P d | 0.5 | W | 0805L050/12XR; 25°C still air, tripped state | 2 | ||
| Typical power in tripped state, 0805L050/15XR | P d | 0.5 | W | 0805L050/15XR; 25°C still air, tripped state | 2 | ||
| Typical power in tripped state, 0805L050/24XR | P d | 0.8 | W | 0805L050/24XR; 25°C still air, tripped state | 2 | ||
| Hold current derating at -40°C | I hold | 0.68 | A | Ambient temperature -40°C (0805L050 derating table) | 5 | ||
| Hold current derating at -20°C | I hold | 0.62 | A | Ambient temperature -20°C (0805L050 derating table) | 5 | ||
| Hold current derating at 0°C | I hold | 0.55 | A | Ambient temperature 0°C (0805L050 derating table) | 5 | ||
| Hold current derating at 25°C | I hold | 0.5 | A | Ambient temperature 25°C (0805L050 derating table) | 5 | ||
| Hold current derating at 40°C | I hold | 0.4 | A | Ambient temperature 40°C (0805L050 derating table) | 5 | ||
| Hold current derating at 50°C | I hold | 0.37 | A | Ambient temperature 50°C (0805L050 derating table) | 5 | ||
| Hold current derating at 60°C | I hold | 0.33 | A | Ambient temperature 60°C (0805L050 derating table) | 5 | ||
| Hold current derating at 70°C | I hold | 0.29 | A | Ambient temperature 70°C (0805L050 derating table) | 5 | ||
| Hold current derating at 85°C | I hold | 0.23 | A | Ambient temperature 85°C (0805L050 derating table) | 5 |
CAD (KiCad official)
- Symbol:
0805L050 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
02a164fafb86ec79, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0805L050
**LUTE** · Resettable Fuses · 0805
0805L050 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 1 | | | A | 25°C still air; minimum current at which device trips (all 0805L050 variants) | 2 |
| Minimum resistance, initial (un-soldered) | R min | 0.1 | | | Ω | Initial un-soldered state (all 0805L050 variants) | 2 |
| Maximum voltage, 0805L050/6XR | V max | | | 6 | Vdc | 0805L050/6XR; maximum voltage device withstands at rated current I max | 2 |
| Maximum voltage, 0805L050/12XR | V max | | | 12 | Vdc | 0805L050/12XR; maximum voltage device withstands at rated current I max | 2 |
| Maximum voltage, 0805L050/15XR | V max | | | 15 | Vdc | 0805L050/15XR; maximum voltage device withstands at rated current I max | 2 |
| Maximum voltage, 0805L050/24XR | V max | | | 24 | Vdc | 0805L050/24XR; maximum voltage device withstands at rated current I max | 2 |
| Maximum fault current | I max | | | 40 | A | All 0805L050 variants; maximum fault current at rated voltage V max | 2 |
| Maximum resistance after trip or reflow | R 1max | | | 0.85 | Ω | 25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s | 2 |
| Maximum time to trip | T trip | | | 0.1 | s | At 8.00 A test current (current column of time-to-trip table) | 2 |
| Passive aging resistance change | | -5 | | 5 | % | +85°C, 1000 hours; typical | 4 |
| Humidity aging resistance change | | -5 | | 5 | % | +85°C, 85% R.H., 168 hours; typical | 4 |
| Thermal shock resistance change | | -33 | | 33 | % | +85°C to -40°C, 20 times; typical | 4 |
| Ambient operating temperature | TA | -40 | | 85 | °C | Ambient operating conditions | 4 |
| Maximum surface temperature in tripped state | | | | 125 | °C | Device in tripped state | 4 |
| Hold current | I hold | | 0.5 | | A | 25°C still air; maximum current device passes without tripping (all 0805L050 variants) | 2 |
| Typical power in tripped state, 0805L050/6XR | P d | | 0.5 | | W | 0805L050/6XR; 25°C still air, tripped state | 2 |
| Typical power in tripped state, 0805L050/12XR | P d | | 0.5 | | W | 0805L050/12XR; 25°C still air, tripped state | 2 |
| Typical power in tripped state, 0805L050/15XR | P d | | 0.5 | | W | 0805L050/15XR; 25°C still air, tripped state | 2 |
| Typical power in tripped state, 0805L050/24XR | P d | | 0.8 | | W | 0805L050/24XR; 25°C still air, tripped state | 2 |
| Hold current derating at -40°C | I hold | | 0.68 | | A | Ambient temperature -40°C (0805L050 derating table) | 5 |
| Hold current derating at -20°C | I hold | | 0.62 | | A | Ambient temperature -20°C (0805L050 derating table) | 5 |
| Hold current derating at 0°C | I hold | | 0.55 | | A | Ambient temperature 0°C (0805L050 derating table) | 5 |
| Hold current derating at 25°C | I hold | | 0.5 | | A | Ambient temperature 25°C (0805L050 derating table) | 5 |
| Hold current derating at 40°C | I hold | | 0.4 | | A | Ambient temperature 40°C (0805L050 derating table) | 5 |
| Hold current derating at 50°C | I hold | | 0.37 | | A | Ambient temperature 50°C (0805L050 derating table) | 5 |
| Hold current derating at 60°C | I hold | | 0.33 | | A | Ambient temperature 60°C (0805L050 derating table) | 5 |
| Hold current derating at 70°C | I hold | | 0.29 | | A | Ambient temperature 70°C (0805L050 derating table) | 5 |
| Hold current derating at 85°C | I hold | | 0.23 | | A | Ambient temperature 85°C (0805L050 derating table) | 5 |
## CAD (KiCad official)
- Symbol: `0805L050`
- Footprint: `Fuse:Fuse_0805_2012Metric`
- 3D model: 0805 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0805l050-15xr-datasheet.pdf) (9 pp, sha256 `02a164fafb86ec79`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0805l050-15xr-datasheet.pdf)