main
Ray Publish 0.1.2 9f14d8c
{
  "slug": "0805l035-6xr",
  "version": "0.1.2",
  "type": "component",
  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
  "tags": [
    "component",
    "circuit protection",
    "0805l035",
    "factory-2.0.0",
    "extractor-text"
  ],
  "dependencies": {},
  "hero": {
    "type": "image",
    "path": "docs/hero.png"
  },
  "files": [
    "page.json",
    "README.md",
    "0805l035-6xr.kicad_sym",
    "0805l035-6xr.kicad_mod",
    "0805l035-6xr.glb",
    "0805l035-6xr.step",
    "0805l035-6xr.lbr",
    "docs/hero.png",
    "docs/0805l035-6xr-datasheet.pdf",
    "viewers/symbol.html",
    "viewers/footprint.html",
    "0805l035-6xr-hero.glb",
    "0805l035-6xr-hero.overlay.json"
  ],
  "component": {
    "mpn": "0805L035/6XR",
    "manufacturer": "LUTE",
    "package": "0805",
    "pin_count": 2,
    "category": "Circuit Protection",
    "subcategory": "Resettable Fuses",
    "datasheet": "https://datasheet.lcsc.com/datasheet/pdf/ffc165e5cddee2ef716ac51b89a76ec7.pdf",
    "parts": {
      "symbol": "0805l035-6xr.kicad_sym",
      "footprint": "0805l035-6xr.kicad_mod",
      "model_3d": "0805l035-6xr-hero.glb",
      "model_3d_step": "0805l035-6xr.step",
      "lbr": "0805l035-6xr.lbr",
      "model_3d_plain": "0805l035-6xr.glb"
    },
    "distributor_links": {
      "lcsc": "C7472562"
    },
    "distributor_check": {
      "checked_at": "2026-11-20T16:46:54Z",
      "source": "Component Ocean /api/assign-pns",
      "digikey": {
        "pn": null,
        "status": "no match"
      },
      "mouser": {
        "pn": null,
        "status": "no match"
      }
    },
    "pins": [
      {
        "number": "1",
        "name": "1",
        "type": "passive",
        "description": "Terminal 1 of an unpolarised fuse; either orientation."
      },
      {
        "number": "2",
        "name": "2",
        "type": "passive",
        "description": "Terminal 2 of an unpolarised fuse; either orientation."
      }
    ],
    "provenance": {
      "extractor": "extract_pins",
      "factory_chain": {
        "factory": "2.0.0",
        "extractor": "extract_pins",
        "primary_model": "two-terminal convention",
        "primary_mode": "convention",
        "consensus_model": null,
        "consensus": "agreed",
        "guards": "pin_guards 0.1: passed",
        "guard_notes": [
          "vision extraction: provenance cannot be text-verified; needs consensus"
        ],
        "pages_sent": 9,
        "cost_usd": 0.0005,
        "at": "2026-11-20T16:46:48"
      },
      "datasheet": {
        "url": "https://datasheet.lcsc.com/datasheet/pdf/ffc165e5cddee2ef716ac51b89a76ec7.pdf",
        "pages": 9,
        "sha256": "02a164fafb86ec79",
        "source_tier": "lcsc",
        "citation": "LUTE datasheet, copy hosted by LCSC"
      },
      "cad": "KiCad official (CC-BY-SA 4.0)",
      "pins": {
        "total": 2,
        "described": 2,
        "cites_pages": true,
        "refuses_to_fabricate": true
      }
    },
    "viewers": {
      "symbol": "viewers/symbol.html",
      "footprint": "viewers/footprint.html"
    },
    "family": {
      "base": "0805l035-30xr",
      "base_mpn": "0805L035/30XR",
      "members": [
        {
          "slug": "0805l035-12xr",
          "mpn": "0805L035/12XR"
        },
        {
          "slug": "0805l035-16xr",
          "mpn": "0805L035/16XR"
        },
        {
          "slug": "0805l035-24xr",
          "mpn": "0805L035/24XR"
        },
        {
          "slug": "0805l035-30xr",
          "mpn": "0805L035/30XR"
        },
        {
          "slug": "0805l035-6xr",
          "mpn": "0805L035/6XR"
        }
      ],
      "siblings": [
        "0805L035/12XR",
        "0805L035/16XR",
        "0805L035/24XR",
        "0805L035/30XR"
      ],
      "old_slug": "0805l035",
      "basis": "one family name (0805L035): the parts the cut-base page adom/0805l035 stood for (slug collision split, data/slug_collisions_2026-11-09.json)"
    },
    "models_3d": [
      {
        "file": "0805l035-6xr.step",
        "role": "plain",
        "up": "Z",
        "units": "mm",
        "origin": "footprint origin = pad-pattern centre",
        "seat": "z = 0",
        "extents_mm": [
          2,
          1.25,
          0.45
        ],
        "zmin_mm": 0,
        "centre_offset_mm": 0,
        "footprint_binding": "identity",
        "sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",
        "checked": "2026-11-20",
        "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"
      }
    ],
    "package_dims": {
      "package_code": "0805",
      "source_page": 3,
      "D": {
        "nom_mm": 2.1,
        "range_mm": [
          2,
          2.2
        ]
      },
      "E1": {
        "nom_mm": 1.35,
        "range_mm": [
          1.2,
          1.5
        ]
      },
      "A": {
        "nom_mm": 0.8,
        "range_mm": [
          0.5,
          1.1
        ]
      },
      "source": "datasheet package drawing, every number found on its page (extract_pins --task dims)",
      "model_check": {
        "file": "0805l035-6xr.step",
        "verdict": "PASS",
        "reasons": [
          "height within the datasheet's package drawing"
        ],
        "by": "factory/package_fit.py"
      }
    }
  },
  "title": "0805L035/6XR",
  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",
  "metadata": {
    "specs": {
      "Manufacturer": "LUTE",
      "Package": "0805",
      "Category": "Circuit Protection",
      "Pins": "2"
    },
    "characteristics": {
      "version": 1,
      "source": "datasheet",
      "datasheet_sha256": "02a164fafb86ec79cb460f9ae36e1480d7ba2674247d8acdfa63655a28eafa35",
      "rows": [
        {
          "name": "Trip current (minimum current at which device trips)",
          "symbol": "I trip",
          "kind": "electrical",
          "unit": "A",
          "min": 0.75,
          "typ": null,
          "max": null,
          "conditions": "25℃ still air; 0805L035/xXR variants (6, 12, 16, 24, 30 V all print 0.75)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Initial minimum resistance",
          "symbol": "R min",
          "kind": "electrical",
          "unit": "Ω",
          "min": 0.2,
          "typ": null,
          "max": null,
          "conditions": "Initial (un-soldered) state; all 0805L035/xXR variants print 0.200",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum resistance after trip or reflow",
          "symbol": "R 1max",
          "kind": "electrical",
          "unit": "Ω",
          "min": null,
          "typ": null,
          "max": 1.2,
          "conditions": "25℃, measured one hour after tripping or 260℃ reflow for 20 sec; all 0805L035/xXR variants print 1.200",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum hold current",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.35,
          "conditions": "25℃ still air; maximum current device passes without tripping",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum time to trip",
          "symbol": "T trip",
          "kind": "timing",
          "unit": "Sec",
          "min": null,
          "typ": null,
          "max": 0.1,
          "conditions": "At 8.00 A time-to-trip test current (time-to-trip max.)",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Time-to-trip test current",
          "symbol": "",
          "kind": "timing",
          "unit": "A",
          "min": null,
          "typ": 8,
          "max": null,
          "conditions": "Current at which the maximum time-to-trip of 0.10 Sec applies",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Maximum fault current withstand",
          "symbol": "I max",
          "kind": "absolute_maximum",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 40,
          "conditions": "At rated voltage (V max); all 0805L035/xXR variants print 40",
          "source_page": 2,
          "source": "datasheet"
        },
        {
          "name": "Ambient operating temperature range",
          "symbol": "TA",
          "kind": "recommended_operating",
          "unit": "℃",
          "min": -40,
          "typ": null,
          "max": 85,
          "conditions": "Ambient operating conditions, series-wide",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Maximum surface temperature in tripped state",
          "symbol": "",
          "kind": "thermal",
          "unit": "℃",
          "min": null,
          "typ": null,
          "max": 125,
          "conditions": "Device in tripped state",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Hold current derating at -40℃ ambient",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.47,
          "conditions": "Ambient -40℃, 0805L035 temperature derating table (maximum hold current)",
          "source_page": 5,
          "source": "datasheet"
        },
        {
          "name": "Hold current derating at 85℃ ambient",
          "symbol": "I hold",
          "kind": "electrical",
          "unit": "A",
          "min": null,
          "typ": null,
          "max": 0.14,
          "conditions": "Ambient 85℃, 0805L035 temperature derating table (maximum hold current)",
          "source_page": 5,
          "source": "datasheet"
        },
        {
          "name": "Resistance change, passive aging",
          "symbol": "",
          "kind": "tolerance",
          "unit": "%",
          "min": -5,
          "typ": null,
          "max": 5,
          "conditions": "+85℃, 1000 hours; printed as ±5% typical",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Resistance change, humidity aging",
          "symbol": "",
          "kind": "tolerance",
          "unit": "%",
          "min": -5,
          "typ": null,
          "max": 5,
          "conditions": "+85℃, 85% R.H., 168 hours; printed as ±5% typical",
          "source_page": 4,
          "source": "datasheet"
        },
        {
          "name": "Resistance change, thermal shock",
          "symbol": "",
          "kind": "tolerance",
          "unit": "%",
          "min": -33,
          "typ": null,
          "max": 33,
          "conditions": "+85℃ to -40℃, 20 times; printed as ±33% typical",
          "source_page": 4,
          "source": "datasheet"
        }
      ]
    }
  },
  "discovery_triggers": [
    "0805l035"
  ],
  "discovery_pitch": "0805L035 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",
  "visibility": "public"
}