LUTE · Resettable Fuses · 0805
0805L035 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current | I hold | 0.35 | A | Maximum current without tripping, 25℃ still air; all 0805L035 voltage variants | 2 | ||
| Trip current | I trip | 0.75 | A | Minimum current at which device trips, 25℃ still air; all 0805L035 voltage variants | 2 | ||
| Maximum fault current | I max | 40 | A | At rated voltage (Vmax); all 0805L035 voltage variants | 2 | ||
| Maximum time to trip | T trip | 0.1 | s | At 8.00 A fault current; all 0805L035 voltage variants | 2 | ||
| Initial minimum resistance | R min | 0.2 | Ω | Initial un-soldered state; all 0805L035 voltage variants | 2 | ||
| Maximum resistance after trip or reflow | R 1max | 1.2 | Ω | 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s; all 0805L035 voltage variants | 2 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | Ambient operating conditions | 4 | |
| Maximum surface temperature in tripped state | 125 | °C | Device in the tripped state | 4 | |||
| Storage temperature | TSTORE | 0 | 30 | °C | Storage condition, 30%-60% RH | 6 | |
| Resistance change, passive aging | -5 | 5 | % | +85°C, 1000 hours; printed as ±5% typical | 4 | ||
| Resistance change, humidity aging | -5 | 5 | % | +85°C, 85% R.H., 168 hours; printed as ±5% typical | 4 | ||
| Resistance change, thermal shock | -33 | 33 | % | +85°C to -40°C, 20 times; printed as ±33% typical | 4 |
CAD (KiCad official)
- Symbol:
0805L035 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
02a164fafb86ec79, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).