← Commit history
package.json+252−2@@ -1,6 +1,6 @@ { "slug": "0805l020-6xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -226,5 +226,255 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L020/6XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "3bfb0bd2cb70f6cc006ce996cc7d816f51c1a908f76d95a653c2323daa150a6e",+ "rows": [+ {+ "name": "Resistance after tripping or reflow (R1max)",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 3.5,+ "conditions": "25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s; same value for all 0805L020 variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial resistance (un-soldered)",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.5,+ "typ": null,+ "max": null,+ "conditions": "Initial un-soldered state; same value for all 0805L020 variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.5,+ "typ": null,+ "max": null,+ "conditions": "25℃ still air; minimum current at which the device trips",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "25℃ still air; maximum current the device passes without tripping",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "At rated voltage (V max) of the specific variant; same value for all 0805L020 variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.02,+ "conditions": "At 8.00 A test current; same value for all 0805L020 variants",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "Tripped state, 25℃ still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient -40℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.28,+ "conditions": "Temperature derating table, ambient -40℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient -20℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.25,+ "conditions": "Temperature derating table, ambient -20℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 0℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.23,+ "conditions": "Temperature derating table, ambient 0℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 25℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.2,+ "conditions": "Temperature derating table, ambient 25℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 40℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.17,+ "conditions": "Temperature derating table, ambient 40℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 50℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.14,+ "conditions": "Temperature derating table, ambient 50℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 60℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.12,+ "conditions": "Temperature derating table, ambient 60℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 70℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.1,+ "conditions": "Temperature derating table, ambient 70℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Hold current at ambient 85℃",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.07,+ "conditions": "Temperature derating table, ambient 85℃",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions for the 0805L series",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in the tripped state",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "TSTORE",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition, 30%-60%RH, sealed packaging",+ "source_page": 10,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l020"+ ],+ "discovery_pitch": "0805L020 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l020-6xr", "title": "0805L020/6XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -488,7 +488,7 @@ "0805l020-6xr-hero.glb", "0805l020-6xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}