← Commit history
package.json+252−2@@ -1,6 +1,6 @@ { "slug": "0805l020-36xr",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -219,5 +219,255 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0805L020/36XR",+ "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0805",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "72b500408f6e5c0f1ebc529639cd280a12bfebc350032e5e4979542098a516ea",+ "rows": [+ {+ "name": "Trip current (minimum)",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.5,+ "typ": null,+ "max": null,+ "conditions": "25°C still air; minimum current at which the device trips",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "at rated voltage (V max)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum time to trip",+ "symbol": "T trip",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 0.02,+ "conditions": "at 8.00 A assigned current",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum initial resistance",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 0.5,+ "typ": null,+ "max": null,+ "conditions": "initial, un-soldered state",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 3.5,+ "conditions": "25°C, measured one hour after tripping or 260°C reflow for 20 s",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "ambient operating conditions",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "storage condition, 30%-60% RH",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "device in tripped state",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.2,+ "max": null,+ "conditions": "25°C still air; maximum current device passes without tripping",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated when tripped",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "tripped state, 25°C still air",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.28,+ "max": null,+ "conditions": "ambient operating temperature -40 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -20 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.25,+ "max": null,+ "conditions": "ambient operating temperature -20 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 0 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.23,+ "max": null,+ "conditions": "ambient operating temperature 0 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 25 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.2,+ "max": null,+ "conditions": "ambient operating temperature 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 40 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.17,+ "max": null,+ "conditions": "ambient operating temperature 40 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 50 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.14,+ "max": null,+ "conditions": "ambient operating temperature 50 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 60 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.12,+ "max": null,+ "conditions": "ambient operating temperature 60 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 70 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.1,+ "max": null,+ "conditions": "ambient operating temperature 70 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 85 °C ambient",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": 0.07,+ "max": null,+ "conditions": "ambient operating temperature 85 °C",+ "source_page": 6,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0805l020"+ ],+ "discovery_pitch": "0805L020 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0805l020-36xr", "title": "0805L020/36XR", "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -481,7 +481,7 @@ "0805l020-36xr-hero.glb", "0805l020-36xr-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}