← Commit history

Publish 0.1.1

Ray ·3175c5fa96 · ·parent a44ffd6
2 files changed +293−7
package.json+288−2
@@ -1,6 +1,6 @@ {   "slug": "0805l010-60wr",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -240,5 +240,291 @@         "by": "factory/package_fit.py"       }     }-  }+  },+  "title": "0805L010/60WR",+  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0805",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "e36ae86f7fa4ccdf109f2a4cb1550eedfd560229695057f6d0476eb27b3a642c",+      "rows": [+        {+          "name": "Hold current (maximum, device passes without tripping)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current (minimum, device trips)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.3,+          "typ": null,+          "max": null,+          "conditions": "25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Minimum resistance, initial un-soldered",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 0.75,+          "typ": null,+          "max": null,+          "conditions": "initial, un-soldered state",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum resistance after trip or reflow",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "25°C, measured 1 h after tripping or 260°C reflow for 20 s (/60WR: 8.000 Ω)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum time to trip",+          "symbol": "",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 1.5,+          "conditions": "at 0.50 A (5× hold current)",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient -40 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.14,+          "conditions": "ambient -40 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient -20 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.12,+          "conditions": "ambient -20 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 0 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.11,+          "conditions": "ambient 0 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 25 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "ambient 25 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 40 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.08,+          "conditions": "ambient 40 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 50 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.07,+          "conditions": "ambient 50 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 60 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.06,+          "conditions": "ambient 60 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 70 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.05,+          "conditions": "ambient 70 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Derated hold current at ambient 85 °C",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.03,+          "conditions": "ambient 85 °C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 1000 hours (typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 85% R.H., 168 hours (typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85°C to -40°C, 20 times (typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "ambient operating conditions",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "device in tripped state",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "storage at 30%-60% RH",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Reflow peak temperature",+          "symbol": "Tp",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "reflow; time within 5°C of peak 20-40 s",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state",+          "symbol": "Pd",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "tripped state, 25°C still air",+          "source_page": 1,+          "source": "datasheet"+        }+      ]+    }+  },+  "discovery_triggers": [+    "0805l010"+  ],+  "discovery_pitch": "0805L010 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+5−5
@@ -4,7 +4,7 @@   "slug": "0805l010-60wr",   "title": "0805L010/60WR",   "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -538,7 +538,7 @@     "0805l010-60wr-hero.glb",     "0805l010-60wr-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file