Made with kicad-footprint-generator 10.0 · KiCad file format 20260206
0805L010
LUTE · Resettable Fuses · 0805
0805L010 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Trip current (minimum) | I trip | 0.3 | A | 25 ℃ still air; family 0805L010, all variants | 2 | ||
| Initial minimum resistance | R min | 0.75 | Ω | Un-soldered initial state; family 0805L010, all variants | 2 | ||
| Maximum time to trip | 1.5 | s | At 0.50 A current; family 0805L010, all variants | 2 | |||
| Maximum surface temperature in tripped state | 125 | ℃ | Device in tripped state | 9 | |||
| Ambient operating temperature range | -40 | 85 | ℃ | Ambient operating conditions | 9 | ||
| Storage temperature | 0 | 30 | ℃ | Storage condition, 30%-60%RH | 11 | ||
| Hold current | I hold | 0.1 | A | 25 ℃ still air; family 0805L010, all variants | 1 | ||
| Power dissipated in tripped state | P d | 0.5 | W | Tripped state, 25 ℃ still air; family 0805L010, all variants | 1 | ||
| Hold current at -40 ℃ (derating table) | I hold | 0.14 | A | Ambient operating temperature -40℃; family 0805L010 | 9 | ||
| Hold current at -20 ℃ (derating table) | I hold | 0.12 | A | Ambient operating temperature -20℃; family 0805L010 | 9 | ||
| Hold current at 0 ℃ (derating table) | I hold | 0.11 | A | Ambient operating temperature 0℃; family 0805L010 | 9 | ||
| Hold current at 25 ℃ (derating table) | I hold | 0.1 | A | Ambient operating temperature 25℃; family 0805L010 | 9 | ||
| Hold current at 40 ℃ (derating table) | I hold | 0.08 | A | Ambient operating temperature 40℃; family 0805L010 | 9 | ||
| Hold current at 50 ℃ (derating table) | I hold | 0.07 | A | Ambient operating temperature 50℃; family 0805L010 | 9 | ||
| Hold current at 60 ℃ (derating table) | I hold | 0.06 | A | Ambient operating temperature 60℃; family 0805L010 | 9 | ||
| Hold current at 70 ℃ (derating table) | I hold | 0.05 | A | Ambient operating temperature 70℃; family 0805L010 | 9 | ||
| Hold current at 85 ℃ (derating table) | I hold | 0.03 | A | Ambient operating temperature 85℃; family 0805L010 | 9 |
CAD (KiCad official)
- Symbol:
0805L010 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (14 pp, sha256
f9ad617ceb3a6f57, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).